datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:HP \HP805A,C,D,S810,G810B

HP \HP805A,C,D,S810,G810B free download

Measuring and test equipment,digital multimeters, analog multimeters, Fluke, Wavetek ... service manuals and repair information

File information:
File name:HP805A_C_D _S810A_G810B.pdf
[preview \HP805A,C,D,S810,G810B]
Size:65 kB
Extension:pdf
Mfg:HP
Model:\HP805A,C,D,S810,G810B 🔎
Original:
Descr:CALIBRATION PROCEDURE FOR HP805A_C_D _S810A_G810B
Group:Electronics > Measuring equipment
Uploaded:28-01-2006
User:jbuske
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name HP805A_C_D _S810A_G810B.pdf

*TB 9-6625-108-50 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR SLOTTED LINE, HEWLETT-PACKARD, MODELS 805A, 805C, 805D, S810A, G810B, J810B, H810B, AND X810B; AND IM-92/U AND IM-92A/U (NASSAU MODEL 230) Headquarters, Department of the Army, Washington, DC 10 December 1973 REPORTING OF ERRORS You can help improve this publication by calling attention to errors and by recommending improvements and stating your reasons for the recommendations. Your letter or DA Form 2028, Recommended Changes to Publications, should be mailed directly to Commander, U. S. Army Aviation and Missile Command, ATTN: AMSAM-TMD-EP, Redstone Arsenal, AL 35898-5000. FAX to DSN 7882313 (commercial 256-842-2313). A reply will be mailed directly to you. SECTION I. IDENTIFICATION AND DESCRIPTION Test instrument identification ... Calibration data card (DA Form 2416)... Calibration description... EQUIPMENT REQUIREMENTS Equipment required ... Accessories required ... CALIBRATION PROCESS FOR SLOTTED LINES, HEWLETT-PACKARAD MODELS 805A, 805C, AND 805D, AND IM-92/U AND IM-92A/U (NASSAU MODEL 230) Preliminary instructions ... Residual VSWR ... Final procedure... CALIBRATION PROCESS FOR SLOTTED LINES, HEWLETT-PACKARD, MODELS S810A, G810B, J810B, H810B, AND X810B Preliminary instructions ... Equipment setup ... Slope and irregularities ... Final procedure... Paragraph 1 2 3 4 5 Page 2 2 2 2 3 II. III. 6 7 8 4 4 7 IV. 9 10 11 12 7 8 10 11 TB 9-6625-108-50 SECTION I IDENTIFICATION AND DESCRIPTION 1. Test Instrument Identification. This bulletin provides instructions for the calibration of Slotted Line, Hewlett-Packard Models 805A, 805C, 805D, S810A, G810B, J810B, H810B, and X810B; and IM-92/U and IM-92A/U (Nassau Model 230). The manufacture's instruction manual was used as the prime data source in compiling these instructions. These slotted lines will be referred to as the "TI" (test instrument) throughout this bulletin. a. Model Variations. Variations among, models are described in table 1 and in text. b. Time and Technique. The time required for this calibration is approximately 2 hours per unit, using the microwave technique. 2. Calibration Data Card (DA Form 2416). Maintenance forms, records, and reports which are to be used by calibration personnel at all calibration levels are listed in and prescribed by TM 38-750. 3. Calibration Description. TI parameters and performance specifications which pertain to this calibration are listed in table 1. Table 1. Calibration Description Test instrument parame

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
HP HP34970A - HP 4145B - HP HP5232A 5532A - HP HP431B_431C - HP HP5232A 5532A - HP HP745A - HP HP8402B -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Perfect Prime Capsule TH0165

script execution: 0.02 s