datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405

Agilent InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405 free download

Various electronics service manuals

File information:
File name:InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405
[preview InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405]
Size:103 kB
Extension:pdf
Mfg:Agilent
Model:InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405 🔎
Original:InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405 🔎
Descr: Agilent InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c20140509 [6].pdf
Group:Electronics > Other
Uploaded:10-11-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name InfSDUHSI0133 U7246A SD UHS-I Card Compliance Test Application Release Notes (Version 01.33) c201405

Agilent U7246A SD UHS-I Compliance Test Application Software Release Notes Agilent U7246A Software Version 1.33.0000 Released Date: 9 May 2014 Minimum Infiniium Oscilloscope Baseline Version: 4.20 (9000 and 90000 series) Enhancements: 1. Added "Trigger Timeout" option in Configure Tab for user to edit the timeout value. 2. Added Threshold Levels tests (Output High Voltage test, VOH and Output Low Voltage test, VOL) Note: This will be the last version to support Infiniium Oscilloscope Baseline Version 4.20. Page 1 of 6 Agilent U7246A Software Version 1.32.0000 Released Date: 14 Aug 2013 Minimum Infiniium Oscilloscope Baseline Version: 4.20 (9000 and 90000 series) Modifications: 1. Fixed Clock Frequency Verification issue. 2. Fixed the histogram issue that disrupts the eye diagram when histogram source change. 3. Changed the triggering method for Precision Mode Test. 4. Turn off all color setting for signal source. 5. Changed the scaling method for Current Consumption Test. 6. Fixed vertical scaling issue for the tests on CMD Lane. 7. Changed the triggering method for Current Consumption Test. 8. Changed the Timeout value for Current Consumption Test 9. Fixed histogram measurement issue Enhancements: 3. Added "tdCK" and "tdRF" option in Configure Tab for Output Delay and Output Hold Time Compensation feature. 4. Added "Maximum Trial" option in Configure Tab to resend command for Current Consumption Test 5. Made enhancement on Current Consumption Test to avoid "MISSMATCH" error. 6. Added Support for MSOX90000 Series Oscilloscopes Page 2 of 6 Agilent U7246A Software Version 1.31.0000 Released Date: 17 November 2011 Minimum Infiniium Oscilloscope Baseline Version: 3.20 (9000 and 90000 series) Modifications: 1. Change of result display sequence in Rise/Fall Time Relation test. 2. Windows 7 x64 driver for USB Interface of TED Host emulator can be found at: C:\ProgramData\Agilent\Infiniium\Apps\SDUHSITest\App\ConsoleA pps\sd_test_win7_x64\ 3. Change of wait time for SD card slot verification. 4. Using probe calibrated value instead of probe default value. Enhancements: 1. Compatible with Window 7 based Oscilloscope. Page 3 of 6 Agilent U7246A Software Version 1.30.0000 Released Date: 8 July 2011 Minimum Infiniium Oscilloscope Baseline Version: 2.50 (9000 and 90000 series) Addition: 1. Added usability of test filter in Setup tab, user can now filter tests according to Speed Mode and DAT/CMD Lane Configuration. Modifications: 1. Upgraded to new usb_sdtestapi.dll. 2. Changed the connection diagram in Current Consumption Test. 3. Changed the Test Pattern Size value for Configure option of `Card Read/Write Start Size for B.O.T' (RC and PM mode). 4. Changed the default value f



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Yamaha RX-V3900 & DSP-AX3900

script execution: 0.08 s