datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent mm-wave Source Modules from OML 252C Inc. for Keysight PSG Signal Generators - Technical Overview 59

Agilent mm-wave Source Modules from OML 252C Inc. for Keysight PSG Signal Generators - Technical Overview 59 free download

Various electronics service manuals

File information:
File name:mm-wave Source Modules from OML_252C Inc. for Keysight PSG Signal Generators - Technical Overview 59
[preview mm-wave Source Modules from OML 252C Inc. for Keysight PSG Signal Generators - Technical Overview 59]
Size:1410 kB
Extension:pdf
Mfg:Agilent
Model:mm-wave Source Modules from OML 252C Inc. for Keysight PSG Signal Generators - Technical Overview 59 🔎
Original:mm-wave Source Modules from OML 252C Inc. for Keysight PSG Signal Generators - Technical Overview 59 🔎
Descr: Agilent mm-wave Source Modules from OML_252C Inc. for Keysight PSG Signal Generators - Technical Overview 5989-2923EN c20140702 [9].pdf
Group:Electronics > Other
Uploaded:06-12-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name mm-wave Source Modules from OML_252C Inc. for Keysight PSG Signal Generators - Technical Overview 59

Keysight Technologies mm-wave Source Modules from OML, Inc. for PSG Signal Generators Technical Overview 50 to 75 GHz 75 to 110 GHz 110 to 170 GHz 60 to 90 GHz 90 to 140 GHz 140 to 220 GHz 220 to 325 GHz 325 to 500 GHz High performance mm-wave Wavelength (mm) source modules extend the 30 20 15 10 8 6 5 4 3 2 1.5 1.0 0.8 100 frequency coverage of the 40 Average atmospheric 20 PSG to 500 GHz. The Key- 10 absorption of milimeter-waves (horizontal propagation) sight Technologies, Inc. PSG signal 4 Attenuation (dB/km) 2 Sea level generators (PSG) provide excellent 1 signal power, resolution, stability, and 0.4 0.2 analog modulation performance for 0.1 0.04 coaxial applications to 67 GHz. Now, 0.02 O2 H2O H2O O2 when paired with new, high power 0.01 0.004 9150 meters altitude mm-wave source modules from OML, 0.002 H2O 0.001 Inc., much of the PSG's capability can 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 300 400 be extended up to 500 GHz to meet Frequency (GHz) the requirements of emerging mm- Figure 1. Atmospheric absorption



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Krell KSA50 clone

script execution: 0.07 s