| File information: | |
| File name: | CP-325.pdf [preview CP-325] |
| Size: | 1296 kB |
| Extension: | |
| Mfg: | Daewoo |
| Model: | CP-325 🔎 CP325 |
| Original: | CP-325 🔎 |
| Descr: | Daewoo Ñhassis CP CP-325 CP-325.pdf |
| Group: | Electronics > Other |
| Uploaded: | 13-02-2022 |
| User: | Anonymous |
| Multipart: | No multipart |
| Information about the files in archive: | ||
| Decompress result: | OK | |
| Extracted files: | 1 | |
File name CP-325.pdf GOODMANS 1418 R 1 General Information MAIN B + (+103V) ADJUSTMENT 1. Receive RETMA pattern signal. VCO/AFT ADJUSTMENT Waveforms 2. Set the picture level to NORMAL mode. 1. APPARATUS CONNECTION & 3. Connect DC voltage meter to the TP7 and PRESETTING CONNECTION Also Covers adjust VR801 for +103V DC. 1. Connect H-out of LSW-480 to X-axis of the DTC-14B1 VUP oscilloscope and V-out of LSW-480 to Y-axis of the oscilloscope. Daewoo CP-325 2. Connect the sweep signal output to TP1. 3. Set ATTENUATOR of LSW-480 to 30dB. 4. Supply 16.5V D.C. voltage (B+) to TP4. 5. Supply 4-5V D.C. voltage to TP5:VCO. 6. Supply 7-8V D.C. voltage to TP5:AFT. Matrix Item | ||