| File information: | |
| File name: | Fax B - KM2030 - U Error Codes.pdf [preview Fax B - KM2030 - U Error Codes] |
| Size: | 25 kB |
| Extension: | |
| Mfg: | Kyocera |
| Model: | Fax B - KM2030 - U Error Codes 🔎 |
| Original: | Fax B - KM2030 - U Error Codes 🔎 |
| Descr: | Kyocera Copiers KM1530_2030 Fax B - KM2030 - U Error Codes.pdf |
| Group: | Electronics > Office equipment > Copiers |
| Uploaded: | 16-06-2022 |
| User: | Anonymous |
| Multipart: | No multipart |
| Information about the files in archive: | ||
| Decompress result: | OK | |
| Extracted files: | 1 | |
File name Fax B - KM2030 - U Error Codes.pdf 3B1 (2-7) U017XX error code table: V.34 transmission Error code Description U01700 A communication error occurred in phase 2 (line probing). U01720 A communication error occurred in phase 4 (modem parameter exchange). U01721 Operation was interrupted due to the absence of a common communication speed between units. U01700: A communication error that occurs at the transmitting unit in the period after transmission of INFO0 before entering phase 3 (primary channel equivalent device training). For example, INFO0/A/Abar (B/Bbar, for polling transmission)/INFOh was not detected. U01720: A communication error that occurs at the transmitting unit in the period after initiating the control channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected. U01721: In the absence of a common communication speed between units (including when an impossible combination of communication speed and symbol speed occurs) after MPh exchange; 1) a DCN signal was received from the destination unit, and the line was cut; or 2) a DIS (NSF, CSI) signal was received from the destination unit and, in response to the signal, the unit transmitted a DCN signal, and the line was cut. (2-8) U018XX error code table: V.34 reception Error code Description U01800 A communication error occurred in phase 2 (line probing). U01810 A communication error occurred in phase 3 (primary channel equivalent device training). U01820 A communication error occurred in phase 4 (modem parameter exchange). U01821 Operation was interrupted due to the absence of a common communication speed between 1-4 units. U01800: A communication error that occurs at the receiver unit in the period after transmission of INFO0 before entering phase 3 (primary channel equivalent device training). For example, INFO0/B/Bbar (A/Abar, for polling reception)/probing tone was not detected. U01810: A communication error that occurs at the receiver unit in phase 3 (primary channel equivalent device training). For example, S/Sbar/PP/TRN was not detected. U01820: A communication error that occurs at the receiver unit in the period after initiating the control channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected. U01821: In the absence of a common communication speed between units (including when an impossible combination of communication speed and symbol speed occurs) after MPh exchange, a DCN signal was transmitted to the de | ||

| Date | User | Rating | Comment |