datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Tektronix TDS 220

Tektronix TDS 220 free download

Oscilloscopes, digital oscilloscopes, Tektronix oscilloscopes, cathode ray ocilloscopes, pc oscilloscopes service manuals and repair information

File information:
File name:Tektronix TDS 220 user instructions for Scope.pdf
[preview TDS 220]
Size:308 kB
Extension:
Mfg:Tektronix
Model:TDS 220 🔎
Original:
Descr:User instructions for Tektronix TDS 220
Group:Electronics > Measuring equipment > Oscilloscopes
Uploaded:07-11-2011
User:busterdog1307
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Tektronix TDS 220 user instructions for Scope.pdf

Tektronix TDS 220 Oscilloscope Operating Instructions 1). Press the White POWER Button located on top of the O-Scope behind the Tektronix name. The Scope will perform a Power-On Self-Test. If nothing happens, make sure that the Scope is plugged in. The Scope will initialize the display with the last settings that were used before the Scope was previously turned off. 2). Connect your input signal to CH 1 (Channel 1). If you have a second input signal, connect it to CH 2 (Channel 2) 3). Press the AUTOSET Button. The Scope will select parameters, and display the waveform(s). This Scope uses Labeled Buttons to select Menus and Unlabeled Buttons to change the parameters within each menu. The five Unlabeled Buttons are to the right of the Display. The items within the column on the 1 right side of the display are the menu parameters. Decide which parameters you wish to change, and select the appropriate Labeled Button. Expanded information can be found in the Tektronix TDS 200-Series User Manual. See page 65 for a Reference List of each Front Panel Labeled Menu Button, and the associated page number explaining the Unlabeled Button Menu options. Copies of this manual can be found in the upper left-hand corner of the Oscilloscope Storage Cabinet, and in the Service Manuals Filing Cabinet in Joyner's office. Look for the Tektronix TDS 220 Oscilloscope folder in the second drawer from the top. To change Channel 1 Waveform Parameters: Press CH 1 MENU. CH1 appears above the right column. Make the following selections with the Unlabeled Buttons: (TDS-200 User Manual, Page 89). Coupling: Choose AC, Ground, or DC. Bandwidth Limit: Choose OFF if you want a 100 MHz display. Choose ON for a 20 MHz display. Volts/Div: "Selects the resolution of the VOLTS/DIV KNOB". Choose Coarse to get the standard 1-2-5 sequence. "Fine changes the resolution to small steps between the coarse settings." Probe: Select 1X when connecting input signal(s) to the Scope with BNC Cables, Patch Cords, or any wires that do not have a Series Resistor between the signal and the Scope. When using a Scope Probe, select 1X or 10X Attenuation on the Probe, and make the same selection on the Scope. Invert: Choose OFF for a Normal Display. Choose ON when using the Math function to subtract one channel from the other. Turn the VOLTS/DIV Knob to change the displayed amplitude of the waveform. Turn the POSITION Knob to move the waveform up or down. The Arrow on the left side of the display indicates the position of the waveform. Channel 1 can be toggled On or Off by pushing the CH 1 MENU Key. Channel 2 can also be turned ON and Off by pushing the CH 2 MENU Key. 2 To set the TRIGGER Parameters, press the TRIGGER MENU Button in the TRIGGER Column on the right side of the Scope. Choose Edge Triggering. Video Triggering is used for NTSC, PAL, and SECAM Television Signals. Slope: "Select to trigger on either the Rising or Falling edge of the signal." Source: "Select the input source as the trigger si

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Tektronix 070-4182-00 2465dmmSvc Nov85 - Tektronix 070-3830-00 2445oper Nov84 - Tektronix 070-6860-00 2465bOper Oct90 - Tektronix 070-6019-01 2465aSvc May87 - Tektronix 070-5857-00 24x5aOptions Jun87 - Tektronix 070-6873-00 2465bSvc Sep89 - Tektronix 070-3829-00 2445svc Jan83 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Philips LX3000D LX3500D

script execution: 0.02 s