datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Sharp AR-M256_M316 AR-M236_M276

Sharp AR-M256_M316 AR-M236_M276 free download

Service manuals and repair information about laser, dot matrix, label printer and ink jet printers of different makes: HP, Canon, Epson, Ricoh, Star, Xerox, Okidata

File information:
File name:TECHNICAL BULLETIN AR-M256_M316 AR-M236_M276.pdf
[preview AR-M256_M316 AR-M236_M276]
Size:96 kB
Extension:rar
Mfg:Sharp
Model:AR-M256_M316 AR-M236_M276 🔎
Original:
Descr:TECHNICAL BULLETIN AR-M256_M316 AR-M236_M276 F5-02" trouble Andromeda Group
Group:Electronics > Computer equipment > Printers
Uploaded:07-01-2016
User:arko123a
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name TECHNICAL BULLETIN AR-M256_M316 AR-M236_M276.pdf

Date: Model: Ref.: Colour: Page: 18 November 2008 See Below DCE737 White 1 of 2 TECHNICAL BULLETIN "F5-02" trouble arising when turning on the main unit in a high-humidity environment 1. Model Name 2. Symptom AR-M256/M316, AR-M236/M276 If an overcurrent flows to the inverter PWB when turning on the main unit in a highhumidity environment, the copy lamp may not light up; it may cause "F5-02" trouble. 3. Description The transistors (Q2/Q3) and capacitor (C2) used on the inverter PWB have been changed to limit overcurrent. · Change and identification of the transistors (Q2/Q3) and capacitor (C2) on the inverter PWB · Identification of the old and new copy lamp units 4. Action Executed from the middle of production in July, 2008 Sharp Electronics (UK) Ltd., Document Systems Support No Model name AR-M256 AR-M257 AR-M258 AR-M316 AR-M317 AR-M318 AR-5625 AR-5631 AR-M236 AR-M237 AR-M276 AR-M277 Version P/G No. 12 -8 Current parts Parts code DUNTK0034QSP1 New parts Parts code DUNTK0034QSP2 Price Q'ty rank BL Parts name Inverter unit Effective time Interchange ability Note 12 -901 13 -8 ALL 11 -8 11 -901 12 -8 CREFL0004QS34 CREFL0004QS36 BT 1 Copy lamp unit 1 Mid'08/7 3 DUNTK0034QSP1 DUNTK0034QSP2 BL Inverter unit Copy lamp unit CREFL0004QS34 CREFL0004QS36 BT 1. Interchangeable. 2. Current type can be used in place of new type. New type cannot be used in place of current type. 3. Current type cannot be used in place of new type. New type can be used in place of current type. 4. Not Interchangeable. 5. Interchangeable if replaced with same types of related parts in use. 6. Others. Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set. Sharp Electronics (UK) Ltd., Document Systems Support

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Sharp ARM236_276 - Sharp AR-FX7 - Sharp AR-M236_M276_AR-M256_M316_AR-5625_5631 - Sharp AR-M236 AR-M237 - Sharp AR-M236_AR-M276 - Sharp AR-M256 AR-M257 AR-M258 AR-M316 AR-M317 AR-M318 AR-5625_5631 - Sharp AR-M256 AR-M257 AR-M258 AR-M316 AR-M317 AR-M318 AR-5625_5631 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Nikko NR819

script execution: 0.02 s