TEK 067-0599-00 Operation.pdf | | 067-0599-00 CALIBRATION FIXTURE
576Cdibrotion
Unit
The 067-0599-00 Calibration Pixture was designed specifically for
calibrating and testing the performance of the 576 Curve Tracer.
Installed in place of the Standard Test Fixture plug-in, the 067-0599-00
provides accurate calibration qLtages and current5 for the horizontal and
vertical deflection circuits and accurate loads for the collector supply and
8tep generator circuits through the external input and output lines at the
test fixture interface. External monitoring of the step generator output
ia available through iln EXTERNAL MONITOR BNC jack providing a 1 V/STEP
(into 10,000 Mj?) output.
The Vectical, Display Offset, Horizonta.1 snd Step Generator switches
of ehe 576 have marching switches on the 067-0599-00 for easy, direct-
reading, Comparison-Style adjusting and checkin |