datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Fluke JW EDN p2

Fluke JW EDN p2 free download

Home electronics, consumer electronics, professional electronics - Television sets (plasma, HDTV, LCD, TFT, Big screen tv), Monitors (TFT-LCD panels, conventional CRT), VCR, DVD, Car Audio etc.

File information:
File name:JW_EDN_p2.pdf
[preview JW EDN p2]
Size:220 kB
Extension:pdf
Mfg:Fluke
Model:JW EDN p2 🔎
Original:JW EDN p2 🔎
Descr: Fluke 720A doc JW_EDN_p2.pdf
Group:Electronics > Documentation
Uploaded:18-01-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name JW_EDN_p2.pdf

designfeature By Jim Williams, Linear Technology Corp PART 2 OF THIS SERIES ON THE DESIGN OF A 20-BIT DAC DIS- CUSSES THE ALL-IMPORTANT TECHNIQUES FOR TESTING THE PERFORMANCE--LINEARITY, SETTLING TIME, AND NOISE--AT SUCH MINUSCULE DATA LEVELS. SEE PART 3 IN THE NEXT ISSUE. Measurement techniques help hit the 1-ppm mark true 20-bit DAC that fits on a circuit board A and costs approximately $100 to build is a de- sign milestone (see EDN, April 12, 2000, pg 95 or www.ednmag.com/ednmag/reg/2001/04122001/ R=100k SEVEN-DECADE SWITCHED WIPER POSITION PERMITS SETTING TO 0.1-PPM LINEARITY 08ms743.htm). Claiming to achieve this level of per- formance is one thing, but proving it with precise (a) measurements is another. The measurement tech- 10k 2k 400 80 niques are at times more exacting than the actual cir- INPUT cuit's design. Part 2 of this series presents approaches and circuits for measuring linearity, settling time, and noise. MEASURE LINEARITY TO 1 PPM Of these three measurements, determining the DAC's linearity requires the greatest effort. Verifying 1-ppm linearity of the DAC and the integral ADC requires special considerations, and, interestingly, some help from the 19th century. Test- Figure 1 80 ing necessitates some form of voltage OUTPUT source that produces equal-amplitude output steps 80 for incremental digital inputs. Additionally, for measurement confidence, it is desirable that the source be substantially more linear than the 1-ppm requirement. This demand is stringent and painful- ly close to the state of the art. The most linear "digital-to-analog" converter is also one of the oldest. Lord Kelvin's KVD (Kelvin- Varley divider) is, in its most developed form, lin- ear to 0.1 ppm. This manually switched device fea- COMMON tures 10 million individual dial settings arranged in (b) seven decades. You can think of the device as a three- 10k terminal potentiometer with fixed "end

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Fluke Y5002 - Fluke JW EDN p1 - Fluke C01 5E3 - Fluke JW EDN p3 - Fluke fe 53 & 54 ii users manual - Fluke dsol11 - Fluke an86f -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Samsung Wiring Diagram

script execution: 0.02 s