datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent HP 34970A Opt. 001 DMM Installation

Agilent HP 34970A Opt. 001 DMM Installation free download

Various electronics service manuals

File information:
File name:HP 34970A Opt. 001 DMM Installation.pdf
[preview HP 34970A Opt. 001 DMM Installation]
Size:73 kB
Extension:pdf
Mfg:Agilent
Model:HP 34970A Opt. 001 DMM Installation 🔎
Original:HP 34970A Opt. 001 DMM Installation 🔎
Descr: Agilent HP 34970A Opt. 001 DMM Installation.pdf
Group:Electronics > Other
Uploaded:26-01-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name HP 34970A Opt. 001 DMM Installation.pdf

Agilent 34970A / Option 001 Internal DMM Assembly Installation Instructions for 34970-80010 Retrofit Kit 1 Disconnect the power cord. 2 Remove the outer cover from the Agilent 34970A. To remove the cover from the instrument, follow the procedures shown in chapter 6 of the 34970A Service Guide. 3 Connect the internal DMM ribbon cable to the main circuit board. Connect the loose end of the grey ribbon cable to connector J202 on the 34970A main circuit board (34970-66511). Press down firmly on the ribbon cable connector and secure the cable in place with the locking clips. Snap the Locking Clips over the top of the connector to secure the Ribbon Cable Ribbon Cable 1 4 Install the internal DMM circuit board into the chassis. Position the internal DMM circuit board inside the instrument chassis by tilting it at an angle as shown below. Be sure to position the circuit board over the tabs in the chassis as shown. Then, lower the assembly into the chassis until it is parallel with the 34970A circuit board. 5 Lock the internal DMM circuit board in place. Slide the internal DMM circuit board to the left (toward the rear of the instrument) until it locks in place. You will hear a click when it is properly locked in place. Make sure that shield is locked in place behind this tab 2 6 Twist the internal DMM input cable. Twist the internal DMM input cable (labeled P101) at least one full turn before plugging it into the backplane connector. If you do not twist the cable as shown, certain specifications will be compromised. 7 Insert the DMM input cable into the backplane connector. Insert the internal DMM input cable into the backplane connector as shown. Press firmly to ensure a good electrical connection. 8 Enable the internal DMM. After installing the internal DMM assembly, you must enable it for operation. From the front-panel, select the DMM ENABLED choice from the Utility menu. From the remote interface, use the INST:DMM command. 3 9 Modify the Labeling on the Rear Panel. If you originally ordered the 34970A without the internal DMM, a solid black circle should be visible above the rear-panel "Opt. 001" label. After installing the internal DMM retrofit kit, be sure to draw an "X" through the black circle using a permanent marker as shown below. Internal DMM is NOT installed.

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Nakamichi MR2

script execution: 0.07 s