datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:LeCroy AP034-OM-E-05

LeCroy AP034-OM-E-05 free download

Various electronics service manuals

File information:
File name:AP034-OM-E-05.pdf
[preview AP034-OM-E-05]
Size:101 kB
Extension:pdf
Mfg:LeCroy
Model:AP034-OM-E-05 🔎
Original:AP034-OM-E-05 🔎
Descr: LeCroy LECROY AP034 AP034-OM-E-05.pdf
Group:Electronics > Other
Uploaded:14-03-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name AP034-OM-E-05.pdf

&DUH DQG 0DLQWHQDQFH &DUH DQG 0DLQWHQDQFH ! CLEANING The exterior of the probe and cable should be cleaned only using a soft cloth moistened with water or isopropyl alcohol. Abrasive agents, strong detergents, or other solvents may damage the probe. Always ensure that the input receptacles are free of debris before connecting accessories. CALIBRATION INTERVAL To guarantee accurate performance, you should have the probe calibrated every 12 months. Avoid exposing the probe to extreme mechanical shock and excessive bending of the cable because these may alter the calibration. SERVICE STRATEGY The AP034 circuits utilize fine pitch surface mount devices; it is, therefore, impractical to attempt repair in the field. Defective probes must be returned to a LeCroy service facility for diagnosis and exchange. A defective probe under warranty will be replaced with a factory refurbished probe. A probe that is not under warranty can be exchanged for a factory refurbished probe. A modest fee is charged for this service. The defective probe must be returned in order to receive credit for the probe core. TROUBLESHOOTING If the probe is not operating properly, the problem may be the way in which it is used. Before assuming the probe is defective, perform the following troubleshooting procedures. A. Trace Off Scale This is typically caused by improper offset setting, or by an input signal that exceeds the probe differential or common mode range. Perform the following: 1. Remove the input signal from the probe, return the offset to zero, and Autobalance the probe. Does the trace return to approximately the center of the graticule? If not, proceed to step 7. AP034-OM-E Rev D ISSUED: January 2000

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
LeCroy 93XXC-OM-E09 - LeCroy LECROY WaveSurfer Getting Started - LeCroy LECROY WJ Series Getting Started - LeCroy 93XXC-OM-E16 - LeCroy 93XXC-OM-E17 - LeCroy 93XXC-OM-E19 - LeCroy 93XXC-OM-E20 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Brother hl1230. 1450. 1470 servicemanual

script execution: 0.01 s