datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Stanford Research Systems www.thinksrs.com-SR245 GPIB

Stanford Research Systems www.thinksrs.com-SR245 GPIB free download

Various electronics service manuals

File information:
File name:www.thinksrs.com-SR245_GPIB.pdf
[preview www.thinksrs.com-SR245 GPIB]
Size:164 kB
Extension:pdf
Mfg:Stanford Research Systems
Model:www.thinksrs.com-SR245 GPIB 🔎
Original:www.thinksrs.com-SR245 GPIB 🔎
Descr: Stanford Research Systems www.thinksrs.com-SR245_GPIB.pdf
Group:Electronics > Other
Uploaded:20-03-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name www.thinksrs.com-SR245_GPIB.pdf

Instructions for using National Instrument Measurement & Automation Explorer with the SR245 Computer Interface These instructions are for the default GPIB address of 25. If using a National Instruments GPIB-USB-HS then you need to connect a standard GPIB cable (at least 1.5 meters in length) in between the National instruments connector and the SR245 1. Setup the SR245 for GPIB communication (see manual page 41). 2. Start up Measurement & Automation Explorer 3. Select the + box next to "Devices and Interfaces" 4. Select "GPIB0 (GPIB-USB-HS)" or (PCI-GPIB) 5. On the upper menu click on "Scan for Instruments" 6. Double click on the instrument with address 25 (Bottom of the page section labeled "Connected Instruments" 7. 8. Select "Communicate with Instrument" on the top menu 9. Power up/down the mainframe (*idn? is an invalid command that locks up the SR245 for the first command) 10.Select "Configure EOS" 11.Type 10 in the EOS Byte box and hit "OK". (ALL COMMANDS SENT TO THE SR245 MUST END WITH A "\r") 12.In the "Send String" dialog box type: i2\r and then click on the "Write" button (This sets the first two ports as inputs and the remaining ports as outputs). The ACTIVITY light on the SR245 should blink the ERROR light should not. 13.Type: s4=3.3\r then the Write button (This sets the output voltage on port 4 to 3.3V). You might want to check it with a meter. 14.Type: ?4\r then the Querry button (This queries the port) 15.The "String Received" box should return the value of port 4.

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Stanford Research Systems www.thinksrs.com-MPA160c - Stanford Research Systems www.thinksrs.com-LDC501m - Stanford Research Systems www.thinksrs.com-SIM983m - Stanford Research Systems www.thinksrs.com-LDC Note 9 Cables - Stanford Research Systems www.thinksrs.com-SIM984c - Stanford Research Systems www.thinksrs.com-LDC Note 7 Scan Function - Stanford Research Systems www.thinksrs.com-LDC Note 6 Modulation Input Divider -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : COMPAQ 472P

script execution: 0.02 s