Philips14PV200/07"N ACT" shows at sw onSwitch the combi off with the mains switch. depress and hold both the wind & rew buttons on the combi while switching back on (Keeping the buttons pressed for around 5 seconds) Release the buttons and this should clear the memory and allow the combi to be setup as normal14-09-04
Philips14PV200/07Dead apart from popping sound at sw onD6391 BYW98 200 rated at 3A s/c - used BY399 in lieu14-09-04