Make | Model | Problem | Solution | Date |
| | | |
Found: 7
|
Bush | 2420 | sound muting on some chans & no search lock | sync pulses at Q403 varying - base bias res R424 750k o/c | 14-09-04 |
Philips | GR2.4 25PT632A/05 | Dead - mains fuse in plug blown | Caused by arcing on/off sw | 14-09-04 |
Philips | GR2.4 29PT5301/05 | Dead with mains I/p fuse o/c | Check for dry joints PSU pri | 14-09-04 |
Philips | GR2.4 29PT632A | Dead with burn up of mains sw & sub pcb | Replacement pcb available from SEME | 14-09-04 |
Philips | GR2.4 29PT632A | No R/C functs after replacement of mains sw sub panel | Check for s/c track on o/p of IR rx | 14-09-04 |
Philips | GR2.4 29PT727B | Tripping with burning smell possible | Tr7545 LOPTr s/c due to C2550 dry joint &/or o/c | 14-09-04 |
Pye | 37KV1242/05B GR1AX | Buzzes , HT correct ( 95v ) . | L5524 OC. | 14-09-04 |