Make | Model | Problem | Solution | Date |
| | | |
Found: 11
|
Philips | 21PV688 | Dead - safety res R3514 & 3592 o/c & D6524 s/c | Now tripping - TDA6107Q on crt base & FOP chip faulty | 14-09-04 |
Philips | 21PV688 | dead, PSU not running | R3338 39R 0.25W o/c (discharge mains cap first!) | 14-09-04 |
Philips | 21PV688 | int. shutting down after frame IC has been replaced | if replaced with later version 6 , also fit frame mof kit 4822 209 16781 | 14-09-04 |
Philips | 21PV688 | No Video remote operation (TV sect ok) | Leave batts out of handset to discharge (several hours) | 14-09-04 |
Philips | 21PV688 | Remote not working | Put in service mode, select 'Service Control' & click 'ok'. Check option codes tally (on label at back of unit). If ok 'Clear' EEPROM | 14-09-04 |
Philips | 21PV688 | Service Mode - entering | Press 'stop' on hset & 'play' on front together for about 5 secs | 14-09-04 |
Philips | 21PV688 | St/by only | Fus res 3514 4R7 3w o/c when TDA8356 IC 7510 fop chip fails | 14-09-04 |
Philips | 21PV688 | tripping, LED flashing red/green | LOPTx u/s (4822 140 10655) | 14-09-04 |
Philips | 21PV688/05 | No pic | No heater supply to crt - R3532 & R3537 4R7 o/c | 14-09-04 |
Philips | 21PV688/05 | Switches to st/by at sw on | Caused by F o/p chip TDA8356 (no heatsinjk compound), also R3512 4R7, R3541 1R | 14-09-04 |
|
Philips | 21PV688/39 | St/by only | Check Field chip & LOPTx - If field chip old type (with "5Y" or lower) marking its the old type - order kit pt no 4822 209 16781 which includes chip & other parts | 14-09-04 |