Make | Model | Problem | Solution | Date |
| | | |
Found: 9
|
Toshiba | 259D9B | Dead | C820/838/840/844/845/846/847/501/866/869 plus the the 2SD1279 at 8UKP(SEME) the 5.6 ohm 20W surge limiter, Q802 a 2SA1012 after all this the power supply ran but was obviously under stress - C462 2700pF 2kv s/c | 14-09-04 |
Toshiba | 259D9B | Dead - st/by led flashes | D819 | 14-09-04 |
Toshiba | 259D9B | Field foldover | C313 220µ | 14-09-04 |
Toshiba | 259D9B | Int loss of sync | Dry joints ICF01 IC on Txt panel | 14-09-04 |
Toshiba | 259D9B | INT NICAM | DRY JOINT ON QG16 5v REG ON NICAM PCB | 14-09-04 |
Toshiba | 259D9B | INT. SOUND | Q196 INT. OPEN | 14-09-04 |
Toshiba | 259D9B | No sound | Sound o/p chip AN7171NK blasted due to hi volts caused by C866 & 869 10µ 50v in psu pri | 14-09-04 |
Toshiba | 259D9B | No sound & o/p IC getting hot | AN7171K o/p ic & check 10µ elects in cct | 14-09-04 |
Toshiba | 259D9B | No sound from cold | Replace 470µ smoothing cap in 12v supply in psu near LOPTx | 14-09-04 |