Make | Model | Problem | Solution | Date |
| | | |
Found: 5
|
Cathay | TV2600 | Int dead for first 10 mins | 12v reg faulty - used TIP32A | 14-09-04 |
Grundig | CUC2600 | Dead - no o/p from psu | C631 100µ in psu | 14-09-04 |
Grundig | CUC2600 | Int blank raster or snowy pic | Tuner | 14-09-04 |
Grundig | CUC2600 | Tuner - snow or blank raster from cold. | Drys in tuner. | 14-09-04 |
ITT | CT2600 CVC1210 | Dead - with ticking noise. | BU208A , T562 ( BD135 ) , R503 ( 100ohm ) if LOPTX hot change it. | 14-09-04 |