Amstrad
CTV1
401
Buzz on sound/caption buzz
adj if o/p coil in tuner or replace tuner
14-09-04
Amstrad
CTV1
401
Dist sound
R356 10k o/c
14-09-04
Amstrad
CTV1
401
Interference bands across screen - affects other tvs in w/s
Mains sw
14-09-04
Amstrad
CTV1
401
Tuning - drift.
Tuner unit.
14-09-04
Amstrad
CTV1
401
Weak & distorted sound.
R356 ( 10k ) o/c
14-09-04
Beon
1
401
Sound distorted
R153 82k hi res
14-09-04
Bush
ITV8
401
11AK20S
St/by only - r/c not operating tv
Initialise remote by pressing arrow L, arrow R & arrow Down as well as "1" at the same time
14-09-04
Crown
CTF1
401
R
Field collapse
R200 4R7 feed to D200 FOP supply o/c - no other FF
14-09-04
GEC
1
401
Int colour - poor line sync
R519 ( 22k ) high.
14-09-04
Goodmans
1
401
FIELD COLLAPSE
C308 ( tantalum ) SITUATED BY PIN 29 TA7698
14-09-04
Goodmans
C1
401
R
Int pic
Dry joints IF module - min ceramic caps
14-09-04
Goodmans
C1
401
R
Pic int off
Dry joints IC502 12v reg
14-09-04
Goodmans
C1
401
R
Snowy pic
Dry joints tuner earths
14-09-04
Goodmans
C1
401
R
St/by only
R802 390k o/c
14-09-04
Grundig
2
401
Tripping
CHECK L-O-TRANS & L519
14-09-04
Grundig
2
401
TRIPS
L519 SHORTED TURNS
14-09-04
Grundig
CUC2
401
BU508 getting too hot.
Change TDA8140.
14-09-04
Grundig
CUC2
401
Dead
R637 1k HT Preset hi res
14-09-04
Grundig
CUC2
401
Dead - faint tripping heard
Dry joints LOPTx
14-09-04
Grundig
CUC2
401
Dead HT oK at PSU o/p
No HT at LOPTx - pri winding o/c
14-09-04
Grundig
CUC2
401
Dead psu tries but fails to start
C633 100µ 25v o/c
14-09-04
Grundig
CUC2
401
Dead with silent tripping
D666 in snubber network s/c
14-09-04
Grundig
CUC2
401
Dead.
D666 s/c.
14-09-04
Grundig
CUC2
401
Goin into standby after few mins.
LOPTX ( If comes on agn from cold ) freezer dont work!
14-09-04
Grundig
CUC2
401
Int dead
HT pot R367 1k
14-09-04
Grundig
CUC2
401
INT FIELD COLLAPSE
D2758 INT OC
14-09-04
Grundig
CUC2
401
Int loss of pic caused by field collapse
26v supply pin 8 TDA2655B was only 4v - D2758 BY298 & C2758 1000µ replaced
14-09-04
Grundig
CUC2
401
Int start up
TDA4600 chopper chip
14-09-04
Grundig
CUC2
401
Int switches to st/by
Tripler
14-09-04
Grundig
CUC2
401
Low controllable sound
Tuner
14-09-04