Beko | 25411ND | Bright raster with sound | Pic can be restored by altering A1 or Focus control - CRT faulty | 14-09-04 |
Beko | NR2541ND | Service mode access | Reqs RCU 14.1 pt no 7M187 (SEME) | 14-09-04 |
Samsung | C1541ZG | WHISTLE ON SOUND | CHANGE RC11 FROM 1uF - 10uF | 14-09-04 |
Samsung | CI541ZG | Dead with relay clicking | C411 100pF 2kv s/c in LOP stage | 14-09-04 |
Samsung | CI541ZG | Dead with relay clicking | C411 100pF 2kv s/c in LOP stage | 14-09-04 |
Samsung | CI541ZG | Frame collapse. | R412 ( 1R 1/2w fusible ) o/c. | 14-09-04 |
Samsung | CI541ZG | Int shut down | Invisible dry joints at chopper trfmr | 14-09-04 |
Samsung | CI541ZG | No red may be int. | Drys Q556 ( CRT PCB ) | 14-09-04 |
Samsung | CI541ZG | No sound - set tripping - black bars on pic. | B5 rail @ 3.4v Infra red Rx leaky ( unplug PA01 - 5 rail restored ) | 14-09-04 |
Samsung | CI541ZG | PSU & LOPT pulsing - no sound. | B5 rail @ 3.4v Infra red Rx leaky ( unplug PA01 - 5 rail restored ) | 14-09-04 |
|
Samsung | CI541ZG | Sound crackling & cutting out. | R618 ( 5.6k ) near audio IC. | 14-09-04 |
Samsung | CI541ZG | Stuck in standby. | Q402 ( 2SD1650 ) s/c. | 14-09-04 |
Samsung | CI541ZG | Will not lock into channels - no sound. | B5 rail @ 3.4v Infra red Rx leaky ( unplug PA01 - 5 rail restored ) | 14-09-04 |
Sony | KVM2541U | Stuck on 1 chan & no R/C response | 2 x resistor packages (4 x 10k) on pluggable tuner/IF/proc board ref RA2 & RA3 - resoldering provided cure | 14-09-04 |