Make | Model | Problem | Solution | Date |
| | | |
Found: 54
|
Goodmans | 2580 | Sound missing | TS90 BC848B sm in sound mute stage | 14-09-04 |
Goodmans | 2580 TX92 | Appears to have field coll with bright line near top | TP91 BC848B & TP96 BC858B sm in psu | 14-09-04 |
Goodmans | 2580 TX92 | Line tearing aft warm up - bad on Txt | Internal arcing of EHT lead at LOPTx end - make sure of a good contact | 14-09-04 |
Goodmans | 2580 TX92 | Sound missing | TS90 BC848B sm | 14-09-04 |
Goodmans | 2580(TX92) | LINE TEARING AFTER SET WARMS UP | CHECK EHT LEAD IS FULLY SLOTTED INTO LOPT | 14-09-04 |
Goodmans | 2580/2880 TX92 | Dead - tripping Led flashes once per sec | TP22 BC337 in PSU | 14-09-04 |
Goodmans | 2580/2880 TX92 | Int sound or screeching with pic present | Dry joints IP08 | 14-09-04 |
Goodmans | 2580/2880 TX92 | No R/C | GM01 has narrow acceptance angle - replace | 14-09-04 |
Goodmans | 2580/2880 TX92 | No sound | TS90 Tr | 14-09-04 |
Goodmans | 2580/2880 TX92 | No sound | TS90 sm BC848B | 14-09-04 |
|
Goodmans | 2580/2880 TX92 | St/by only | RP62 2R2 | 14-09-04 |
Goodmans | 2580A/2880A ICC9 | Field cramp at top - int | DF31 - replace with BA157 | 14-09-04 |
Goodmans | GD2580 | Loud whistle | LL26 coil in line stage - hot melt glue used | 14-09-04 |
Goodmans | GD2580 TX92 | E/W settings different at sw on & int reverts to st/by | IF02 STV2145 | 14-09-04 |
Goodmans | GD2580 TX92 | Int dead | dry joints CP13 1nF5 1.6kv | 14-09-04 |
Goodmans | GD2580B TX92 | Installation menu entering | Sw TV to st/by then sw off at mains. Sw on TV whilst holding "P" button in on front until Lang menu appears | 14-09-04 |
Matsui | 1580 | Dead | C818 1µ 50v; R811; C810 22µ 160v; C806 1000µ 16v; C808 1000µ 25v;R409 2k7; C410 100µ 16v | 14-09-04 |
Matsui | 1580 | Dead - F851 fuse shattered | Q801 BU508A s/c - caused by R808 270k o/c | 14-09-04 |
Matsui | 1580 | Dead - fuse F851 shattered. | | 14-09-04 |
Matsui | 1580 | Int vision at switch on. | IC TDA3562A must use TFK ( Telefunken ) type. | 14-09-04 |
Matsui | 1580 | No pic at sw on until A1's adj | Replaced TDA3562A & change R513 from 180k to 68k & R515 from 120k to 150k | 14-09-04 |
Matsui | 1580 | SET SQUEALS AND SWITCHES OFF | C818 1uF 50v IN POWER SUPPLY | 14-09-04 |
Matsui | 1580 | TRIPPING , SUPPLY AT TP44 160v | C818 1uF 50v | 14-09-04 |
Matsui | 1580 | Trips off with squeal - high HT | C818 1µ 50v - once replaced HT normal at 112v | 14-09-04 |
Matsui | 2580 | Dead | Check R808 270k & TDA4601 | 14-09-04 |
Matsui | 2580 | Dead | CHECK R808 270K , TDA4601 | 14-09-04 |
Matsui | 2580 | Dead - Low HT rail | C808 1mfd OC | 14-09-04 |
Matsui | 2580 | DEAD BUT STANDBY LED ON | CHECK HT , IF LOW C808 1uF , 63V | 14-09-04 |
Matsui | 2580 | Dead or int goes to st/by | Check 145v HT at at scan coil interlock, if missing check link between L805 & R826 for poor joints - also check fuseholder for tightness | 14-09-04 |
Matsui | 2580 | DEAD STBY LIGHT ON | HT LOW AT 70v IF ON BUTTON HELD IN HT VARIES FROM 70v - 100v C808 1uF 63v | 14-09-04 |