Make | Model | Problem | Solution | Date |
| | | |
Found: 185
|
Beko | NR26114 | Lack of height with line through | Field scan coils (read 30R) | 14-09-04 |
Beko | NR26114R | Field collapse | R126 4R7 0/c, C113 100n s/c - sm & check TDA3653B | 14-09-04 |
Bush | BC6111 | Tuning drift. | Check/replace 9Z1 | 14-09-04 |
Cathay | TV2610 | L501 resistor smoking | TDA4503 supply feed safety res o/c - 1R5 | 14-09-04 |
Cathay | TV2610 | Line collapse - sound ok | Big boost cap 1µ8 leaky | 14-09-04 |
Decca | 161 | Dead - HT supply 400v | Q501 ZTX651 12v reg, D503 12v zener | 14-09-04 |
Decca | 161 | No sound or led display | LL01 choke dry joint | 14-09-04 |
Decca | 161 | Tripping - Rapid. | 12k R507 & R508 resistors feeding 12v stab o/c. | 14-09-04 |
Decca | 161 | Tripping. | R508 ( 12k ) o/c. | 14-09-04 |
Ferguson | 1612 | No Sound. | Sound IC TDA3190P | 14-09-04 |
|
Ferguson | C3615U Combi | Switches off aft 10 secs with tape jammed | RW002 1R 1w safety res on deck pcb - also check fuse link FW003 (behind on/off sw near white ribbon conn) | 14-09-04 |
Ferguson | C3615UT | Hotel mode removal | Press simultaneously on the PR-, STOP and AC on/off button on the front of the combi. Adjust using arrow keys on the remote, press ok. | 14-09-04 |
Ferguson | C3615UT | Hotel mode reset | Press PR-, STOP & AC on/off button on front of combi. Adj using arrow keys on R/C, press ok. | 14-09-04 |
Ferguson | C3615UT | No R/C response | 3 legged IR Rx faulty | 14-09-04 |
Ferguson | C3615UT | Txt int lost | QX51 27Mhz Xtal on Txt pcb replaced | 14-09-04 |
Ferguson | TX807 M3615UT | Dead apart from red LED pulsing - In Child Lock | To release - Sw on TV at mains whilst holding in Magenta Txt key | 14-09-04 |
Ferguson | TX807 M3615UT | LED stays green for 6 secs at sw on then reverts to st/by | DL04 BY288 in E/W mod cct leaky | 14-09-04 |
Goldstar | CIS4361 | No picture - sound ok | no crt htrs due to taernished pins on 4 pin connector by Loptx | 14-09-04 |
Goldstar | CIS4361 | No picture. | 4 Pin connector by LOPT pins tarnished ( feed to heaters ) | 14-09-04 |
Goldstar | CIT610S | St/by only with squeal | C830 220µ 25v o/c, R808 270k replaced as a precaution, C818 1µ 50v o/c, C802 100µ 25v hi esr, R811 1R ?w o/c | 14-09-04 |
Goodmans | 1465TS L6.1 | Dead - psu blown due to EHT lead arcing in LOPTx | Fit PSU kit 482231010663 & LOPTx 482214010562 & LOPTr | 14-09-04 |
Goodmans | 1465TS L6.1 | Weak contrast - black vert lines | C2427 33nF 250v in beam lim | 14-09-04 |
Grundig | 6100 | No picture - sound ok. | D2764 ( SKE2F1 ) o/c. | 14-09-04 |
Grundig | 6100 | Tuning drift. | Warped cabinet pushing onto p/b unit. | 14-09-04 |
Grundig | 6610GB | Int no colour. | C861 , C863 leaky. | 14-09-04 |
Grundig | 8610 | Hum bar effect at centre & width reduced. | +D ( 36v ) supply reservior cap. | 14-09-04 |
Grundig | CUC 6360 / CUC 6361/ CUC 6365 | Intermittent no picture, it would fade out with the width getting smaller.
HT 150volts was down to 100volts. | C672 100 MFD @ 250VW | 14-09-04 |
Grundig | CUC 6360 / CUC 6361/ CUC 6365 | No picture, but HT / EHT all ok, picture was blanked out. | CT5066 BC858. This is a s.m. device on the video processing pcb. It is on p22 of ic 5040. | 14-09-04 |
Grundig | CUC5361 | Int rolling/shaking pic | Dry joints on earthing frame of chassis | 14-09-04 |
Grundig | CUC5361 | trips on high brill - no beam lim action | beam lim volts to pin 12 RGB module. Volts at pin 15 IC5150 should fall as brill increases. It did but chip was u/s | 14-09-04 |