Goldstar | RC7031 | Critical AGC level adjustment cut off | C707 4.7mfd 50v | 14-09-04 |
Mitsubishi | CT3703STX | Dead - LOPTr s/c | LOPTr 2SD1879 replaced & C908 10µ 100v, C909 47µ 50v | 14-09-04 |
Mitsubishi | CT3703STX | E/W & width | CHECK R5005 / R5006 FOR DRY JOINTS | 14-09-04 |
Mitsubishi | CT3703STX | No pic - ok thro' scart | Check for dry joints in IF can | 14-09-04 |
Sharp | C3703H | Dead fuse intact no output PSU | STR40090 u/s | 14-09-04 |
Sharp | C3703H | dist sound & int on chan change - no vol control | T301 sound discrim coil faulty - set up with can fitted | 14-09-04 |
Sharp | C3703H 7PS | Dead - no o/p from psu | STR40090 psu chopper chip | 14-09-04 |
Watson | FA7039 11AK19 | Dead with LOPTr s/c | HT at 170v on dummy load - R823 130k hi at 170k | 14-09-04 |