Make | Model | Problem | Solution | Date |
| | | |
Found: 8
|
Grundig | CUC73xx series ST55-725 | Power supply blow up | Caused by C60029 470pF 1.6KV which was badly dry jointed. Only seems to affect sets fitted with blue cap - the orange ones are ok. | 14-09-04 |
Grundig | CUC73xx series ST55-725 | Sound faulty | the soldered joints on C60029 were very poor | 14-09-04 |
ITT | CT3725/1 80R | Stuck in standby - with a noise from LTB. | D732 ( BY500-400 ) s/c can use a RGP30 | 14-09-04 |
JVC | 7255EE-A | Won't come out of standby. | PS, near AN5900 change 2caps 220uF 3caps 10uF and 1cap 47uF. | 14-09-04 |
JVC | 7255EE-A | Won't come out of standby. | PS, near AN5900 change 2caps 220uF 3caps 10uF and 1cap 47uF. | 14-09-04 |
JVC | 7255GB | St/by only | C33 220µ 16v & check for drys | 14-09-04 |
NEI | MP37H1 3724/3725 | St/by only - very int when checking around psu | N005 SYV5180 in psu | 14-09-04 |
Nokia | 3725 | weak lum | replaced txt pcb | 14-09-04 |