B & O | 2500 LX2802 | Int reverts to st/by briefly with blank raster on return | Tr6 - use BC338-40 as replacement - checks ok out of cct | 14-09-04 |
B & O | Beovision 8802 Type 7001 | Blank raster, no sound, OSD OK | R1 1,5Ohm o/c, TR1-TR2 BC 338-25 o/c, D1 13V Zener s/c
| 14-09-04 |
B&O | LX2802 | no raster field collapse | TDA2170 u/s nla TDA8172 in lieu c/w adaptor + 4R78 3k3, 4R85 0R56 | 14-09-04 |
Schneider | CTV2802 | Arcing LOPTx | Loptx replaced pt no HR8320 - will fit with some slight mod to clips etc | 14-09-04 |
Schneider | STV2802 TV9.1 | Service mode entering | Press red & blue buttons on RC together. Press prog down & vol up on TV together within 5 secs. Select items using up/down buttons. Parameters use red button. Adjust value using volume +/-. Press OK button to store value. Leave service mode by pressing TV button. | 14-09-04 |
Schneider | STV2802T | Dead - mains fuse blown | Mains bridge rect s/c (looks under rated) | 14-09-04 |