Make | Model | Problem | Solution | Date |
| | | |
Found: 10
|
Baird | RR5990 | Almost total field collapse | dry joints IC453 | 14-09-04 |
Ferguson | 9900 | Tuning - will not tune in. | Check for 33v supply & a 15k resistor 2watt change it. | 14-09-04 |
Goldstar | CI9902F | St/by only | R761 2k7 hi res | 14-09-04 |
Goldstar | CI9902F | Stuck in standby. | R761 2k7 HIGH | 14-09-04 |
Goldstar | CI990LT | St/by only - relay clicks at sw on | HT low at 60v instead 115v - check C8075 33µ 160v | 14-09-04 |
Goldstar | CIT9902 PC04 | Field fault | D301(1N4007 used) | 14-09-04 |
Goldstar | CIT9902F | Dead | No 110v to lop stage - D803S dry jointed in mains bridge rect cct | 14-09-04 |
Goldstar | CIT9902F | Not starting , HT low. | C807S OC 33uF. | 14-09-04 |
Goldstar | CIT9902F | St/by only | Osc feed to IC701 X701 10Mhz Xtal u/s | 14-09-04 |