Make | Model | Problem | Solution | Date |
| | | |
Found: 7
|
Philips | 52ZY3535 Anubis B AA | No pic, sound ok with faint burning smell | No Filed - replace overheated R3452 4R7, R3450 3R9 & IC7400 TDA3653B | 14-09-04 |
Philips | Anubis B AA | Dead - chopper tr s/c | Replaced opto IC7514 CNR50, Control chip IC7500 & chopper tr | 14-09-04 |
Philips | Anubis B-AA | Hor grey line over pic | Field scan has osc on it - C4213 10nF o/c | 14-09-04 |
Philips | Anubis B-AA | LED flashing with "ER4" displayed | Fault in Txt - lines only in Txt - Xtal 1701 27Mhz faulty | 14-09-04 |
Philips | Anubis B-AA | Removing "Demo" mode | Switch on whilst holding in "VOL-" & "Prog+" in together. | 14-09-04 |
Philips | Anubis B-AA | When replacing EEPROM IC7685 ST24C02P | Default language is Norwegian! & childlock (Barnlas)active. To clear childlock select spec functs option C on main menu. Next menu - Barnlas as option A - set to Fran (off). Then able to set up other parameters | 14-09-04 |
Philips | Anubis BAA | Dead with pulsing squeak | C2540 2200µ 16v leaky | 14-09-04 |