Make | Model | Problem | Solution | Date |
| | | |
Found: 9
|
Sharp | CA10 59DS03H | Dead apart from neon glowing | R703/705 68k hi res | 14-09-04 |
Sharp | CA10 59DS03H | Dead apart from power light | 2 x 560k start up res hidden under chopper heatsink | 14-09-04 |
Sharp | CA10 59DS03H | Dead with mains fuse o/c | Q701 chopper FET s/c RH-TX0166BM22, D712 zener RH-EX0419BM22, BUH515 LOPTr - if stuck in st/by aft replacement Q702 BC338 in psu s/c | 14-09-04 |
Sharp | CA10 59DS03H | Field - no pic at top ? of raster | Field stage is supplied with + & -ve supplies fused by F601/2. Check these & Q501/2. Q501 faulty & replaced with a IRFI9020 (uprated device) | 14-09-04 |
Sharp | CA10 59DS03H | Field scan at top stretched | Scan coils faulty - do not run for long - risk of crt neck damage | 14-09-04 |
Sharp | CA10 59DS03H | FRAME COLLAPSE | REPLACE F602 | 14-09-04 |
Sharp | CA10 59DS03H | NO REMOTE OR KEYPAD FUNCTIONS | REPLACE R705 68K | 14-09-04 |
Sharp | CA10 59DS03H | PARTIAL FRAME COLLAPSE | REPLACE F0601 F0602 AT REAR OF PCB | 14-09-04 |