Make | Model | Problem | Solution | Date |
| | | |
Found: 4
|
Sanyo | CE28WN4B | Excess height & E-W faulty | Fit mod kit B10H04N1C or B10H04D0L if Dolby Pro Logic set | 14-09-04 |
Sanyo | CE28WN4B | Int Cuts out with LED flashing (prot mode) | To disable prot mode dis R648 - after a while crt heaters went out due to dry joint | 14-09-04 |
Sanyo | CE28WN4B | St/by only with LED flashing | R620 120k hi res | 14-09-04 |
Sanyo | EB6-A28 CE28WN4-B-01 | Service mode access | Push green fastext key while pushing prog down key on front of set. To adjust geometry make sure pic size is set to "Full" before starting, select "Wide" under options & select parameter using prog + & - adj with vol + & - and switch off to store. Mod kit available from SEME for this fault | 14-09-04 |