Make | Model | Problem | Solution | Date |
| | | |
Found: 6
|
Grundig | Super color 8472/8672/8272/8872/9272 | R621(6,2ohms) smokes immediately after switch-on. | Replace thyristor Ty503 type17127 | 14-09-04 |
Grundig | Super color 8472/8672/8272/8872/9272 | R621(6,2ohms) smokes immediately after switch-on. | Replace thyristor Ty503 type17127 | 14-09-04 |
Grundig | Super color 8472/8672/8272/8872/9272 | Won't search. | Pin 5 of syntheseizer module, should have 3,5 volts. If not, change R4111 (1,8 volts). | 14-09-04 |
Grundig | Super Color 8615/8415/8215/8115 | Won't start, no EHT present. | Di518 Sced. It's located behind the large 15uF nonpolar cap.(C532) | 14-09-04 |
ITT | Ideal color 3332GR | Won't start, going to stby. | Change polyester cap C709 connected between B-E of horizontal output Tr. Shorts hor. drive to ground | 14-09-04 |
Nordmende | Color 3636 | It takes several minutes to start. When it starts, reduced width. | Change CL27 2,2uF, next to hor. driver transistor. | 14-09-04 |