Make | Model | Problem | Solution | Date |
| | | |
Found: 35
|
Goodmans | COMPACT 110 | Dead | CHECK REG , AND FIELD CHIP AN5512 Pt No. CPC*HN5652AN5512 | 14-09-04 |
Goodmans | Compact 110 | Dead | High HT can cause havoc rendering set beyond repair - signs are bulging elects in fop stage | 14-09-04 |
|
Goodmans | Compact 110 | Dead | Remove black glue, check 180k start up resistors & 47µ caps in psu | 14-09-04 |
Goodmans | Compact 110 | Dead | Check CP22 & 30 100µ & RP04 & 05 180k. QP01 2SA1012 - use BD224C in lieu. ZP06 6v8 zener & RV01 4R7 & ICV1 TDA3653 | 14-09-04 |
Goodmans | Compact 110 | Dead - no psu o/p | DP09 s/c, RP20 burnt up | 14-09-04 |
Goodmans | Compact 110 | Dead - no psu operation | R5 180k o/c | 14-09-04 |
Goodmans | Compact 110 | Dead - psu blows up | Onwa kit available | 14-09-04 |
Goodmans | Compact 110 | Dead after ran on 24v instead of 12v | QPD1 2SB826 reg s/c, when replaced field collapse - TDA3653B fop chip & feed res burnt - used 4R7 1/4w & replace HT pot for int pic size with lines | 14-09-04 |
Goodmans | Compact 110 | Dead -went off with a flash | burn up on pcb between CP10 & link adjacent to RP06 - RP06 39R 7w o/c, dry joints RP09 & remove black glue | 14-09-04 |
Goodmans | Compact 110 | Field - lack of height with bottom compressed | RP05 8k2 3w metal film o/c | 14-09-04 |
Goodmans | Compact 110 | Int field collapse with short, bright hor line | Dry joint A1/focus earth pin on LOPTx | 14-09-04 |
Goodmans | Compact 110 | Line collapse | CH01 4µ7 50v bipolar o/c | 14-09-04 |
Goodmans | Compact 110 | Line collapse & no sound | Dry joint LH01 | 14-09-04 |
Goodmans | Compact 110 | St/by only | ZP06 8v2 zener (set had been connected to 12v wrong way round) - Mk 1 version | 14-09-04 |
Goodmans | Compact 110/2 | No sound/pic with LED lit & 12v present | DH04 s/c pt no ACTI13051025 | 14-09-04 |
Goodmans | Compact110 | Line drive int | CH03 10mfd 25v | 14-09-04 |
Goodmans | Compact110 | Whistling/whining in st/by | Reg 10.8v not dropped to 0v - Micro pin30 not shutting off reg (should be 12v in st/by) - micro faulty | 14-09-04 |
Goodmans | Compact110 | Won't go into st/by | CR02 0.1mfd o/c | 14-09-04 |
Goodmans | Compact110/2 | Line collapse | Dry joints LH01 & CH01 in line coil coupling | 14-09-04 |
Hinari | CT11 | Tripping | Works ok with Q117 on main pcb dis'd - purpose of this tr? | 14-09-04 |
Hinari | CT11 | Tripping. | Remove base of Q17 the set will work without it! | 14-09-04 |
Hinari | CT11 | TRIPS IF FRONT PANEL DISCONNECTED SET RUNS | REMOVE BASE Q17 !! | 14-09-04 |
|
Samsung | CI3373Z SCT11B/D | Service mode access | Stby/P.STD/HELP/SLEEP/POWER ON. Controls VOL +/- CHANNEL +/- EXIT with Status,{all on r/c} | 14-09-04 |
Samsung | CI5079T SCT11D | Blue screen with no sound - menus partly off top of screen | Eeprom settings lost - with SAA5290ZP-026 set option byte to 5D, with-042 suffix Eeprom set option byte to CA; still no signals present - pin 1 of micro s/c to chassis - new micro reqd | 14-09-04 |
Samsung | CI5373 SCT11B | Tripping | LOPTx arcing - when replaced field coll; HIC301 VPG101 hybrid chip | 14-09-04 |
Samsung | CI5373 SCT11D | Apparent blank raster | FOPT chip was faulty | 14-09-04 |
Samsung | CI5373 SCT11D | Service mode access | Press St/by, Std Pic button, Help, Sleep, Power On. Parameters selected with Ch+/Ch- & changed using Vol+/-; SBT = 44, SCT = 32, RC = 0, GC = 0, BC = 0, RG = 32, BG = 32. Press 'Status' to store & exit | 14-09-04 |
Samsung | SCT11B | dead, fuse blown | replace C803 2n2 800V (2303-000163 or A1102-0331), DZ801 R2KN (0403-000691), IC801 (AA13-20004P), HC801 (AA13-20004M). Note: HC801 and IC801 must be "C" version! | 14-09-04 |
Samsung | SCT11B CI5079T | frame collapse | IC201 MS2309BSP faulty, no drive from pin 18 (1204000431) | 14-09-04 |
Samsung | SCT11B CI5079T | frame collapse | R410 o/c | 14-09-04 |