Make | Model | Problem | Solution | Date |
| | | |
Found: 10
|
Sharp | DV3760 | Dead | s/c on ht line traced to LOPTx | 14-09-04 |
Sharp | DV3760 | Pic displaced 3" to right | R604 seems to be the cause (wrong value?) removing it centralised pic | 14-09-04 |
Sharp | DV3760 | Tripping PSU & LED red/green flashing | C604 1000µ 16v in sec of psu | 14-09-04 |
Sharp | DV3760 4BSA | Shuts down straight away at sw on | Replace LOPTx (HR 7559) plus R649 27R 1/2W, R637 27R 1/2W, R640 56R 1/2 W + 2 elect caps between base/emitter Q1010 | 14-09-04 |
Sharp | DV3760H | Dead | S/C across LOP stage; D601 1N4937 600v 1A s/c | 14-09-04 |
Sharp | DV3760H | Dead - no o/p from psu | D601 1N4997 HT rect leaky | 14-09-04 |
SHARP | DV3760H | DEAD WITH S/C ACROSS LINE O/P TRANSISTOR | CHECK D601 1N4937 | 14-09-04 |
Sharp | DV3760H | VERTICAL STRIPES ON LEFT SIDE ESP DARK SCENES | FIT 1K8 IN PLACE OF JUMPER WIRE R895 Sharp VRD-RA2HD182J | 14-09-04 |
Sharp | DV3760H 4BSA | Dead but all psu secs ok apart from 13v | D602 faulty tho' measured ok | 14-09-04 |
Sharp | DV3760H 4BSA | No start up | C604 1000mfd 16v o/c | 14-09-04 |