Make | Model | Problem | Solution | Date |
| | | |
Found: 6
|
Sony | FE-1 KV25K5U | Int reverts to st/by with LED flashing 5 times | CRT internal s/c - replaced under guarantee - very prone to this fault apparently | 14-09-04 |
Sony | FE-1 KV25K5U | lines across screen, frame IC running hot | C506 0.01 uF | 14-09-04 |
Sony | FE-1 KV25K5U | not starting up, LED flashes 4 times | T511 breaking down at switch on, replace T511 (145326411 for 25", 145326511 for 29") | 14-09-04 |
Sony | FE1 KV25K5U | Dead with LED flashing 4 times | Check for 9v at pins 33 & 34 IC301. If present, check R546 47R 1/2w for o/c (135v Line dr supply) | 14-09-04 |
Sony | FE1 KV25K5U | No R/C op - hset ok | D011 5v6 zener on o/p of Rx leaky | 14-09-04 |
Sony | FE1 KV25K5U | Trips off with a crack - LED flashes 5x | CRT faulty | 14-09-04 |