Sony
FE2
Line tearing, ragged verticals, arcing noise.
incorrectly fitted EHT lead at the LOPT end. Follow bulletin reference TV05900 for correct fitting.
14-09-04
Sony
FE2
Reverts to st/by at sw on with 2 or 5 flashes from LED
5 flashes indicates an AKB error (Grey Scale Correction). This is normally due to LOP shut down & there is no EHT or sec line volts. Normally due to faulty R618 (270K ohm). This res is in the current sensing cct & could therefore potentially give you an over-current error (2 flashes).
14-09-04
Sony
FE2 KV14LM1U etc
LED flashes 5 times - sound but no pic aft initial EHT rush
R618 270k in current sensing cct - roughly centre of board close to Q602
14-09-04
Sony
FE2 KV32DX40U
Dead- no st/by 5v
Q601 2SA1037AK U/S on A board. Part No 872902649
14-09-04