Make | Model | Problem | Solution | Date |
| | | |
Found: 5
|
Philips | FL1.2-AB | Bad focus or focus varies in a new set or after CRT replacement | Possible solution:
Short circuit the focus and the G2 pins of the picture tube with the
aquadag coating. Switch the set on for approximately 5 seconds.
After this return the set to its original condition. Check if the
focus adjusted normally. If not repla | 14-09-04 |
Philips | FL1.2-AB | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL1.2-AB | Low Brightness TXT and OSD, Picture OK | If this condition occurs, check the Option Codes.
Resetting the Option Code numbers as per the Service Manual provided
the cure.
| 14-09-04 |
Philips | FL1.2-AB | Overview of SOPS repair kits | Overview of SOPS repair kits
----------------------------
FL1.0 AG00 upto AG03 4822 310 20492
FL1.0 AG04 and higher 4822 310 31921
FL1.0S 4822 310 31924
FL1.1 25" and 28" 4822 310 31919
FL1.1 33" 4822 310 31932
FL1.1S | 14-09-04 |
Philips | FL1.2-AB | Picture twists from top | Voltage of pin 8-IC7450 (TDA3654Q) on the LSP has raised to ca. 20 V.
Check diode 6451 (BZX79/C3V6; 5322 130 34834 or
BZX79/C10; 4822 130 61219)
| 14-09-04 |