MakeModelProblemSolutionDate
Found: 18
PhilipsFL1.20Bad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla14-09-04
PhilipsFL1.20Bad pict. No menu. Dark bars over pict. Red pict. in dig.scan mode.+5V was 4,3V instead of 5,1V. IC7551 (LM358N 4822 209 70672) defective. IC7209 (SAA7158 4822 209 31059) Bendic defective. 14-09-04

PhilipsFL1.20Bad picture. Picture scrolls. No RC reaction.+5V was 4,1V instead of 5,1V. Replace IC7551 (LM358N; 4822 209 70672) 14-09-04
PhilipsFL1.20Blank picture. OSD not synchronised and too large, no TXT.Check/replace memory IC 7900 (ST24C08CB1; 4822 209 32283). 14-09-04
PhilipsFL1.20Both languages can be heard by Dual Nicam signalsFor FL1-PTV change the software into V89; 4822 900 10732 For all other FL sets change the software into V88; 4822 900 10723 REMARKS :Introduced in production from week 9614 onwards.14-09-04
PhilipsFL1.20Correction to Product Survey 1996-4Correction to Product Survey 1996-4 (4822 727 21505) ---------------------------------------------------- On page PCS 41989 is mentioned at: FL1.10 AG11 and higher: Control panel 4822 212 31708 FL1.17 AG20 : Control panel 4822 212 31708 FL14-09-04
PhilipsFL1.20Correction to service information FL 95.01Correction to service information FL 95.01 ------------------------------------------ Correction in the overview of 100Hz and Proscan boxen. The replacement for service code 4822 212 30534 must be 4822 212 31231 The replacement for service code 4822 2114-09-04
PhilipsFL1.20Dark picture, only green led, no menu or OSD.+5V supply was 4,1V. Voltage D6551 was 4,3V instead of 5,6V. Check/replace D6551 (4822 130 80954). 14-09-04
PhilipsFL1.20Four dark bars over the picture.The +5 volt was 5.6 volt instead of 5.1 volt. Check/replace IC7551 (4822 209 70672). 14-09-04
PhilipsFL1.20Low Brightness TXT and OSD, Picture OKIf this condition occurs, check the Option Codes. Resetting the Option Code numbers as per the Service Manual provided the cure. 14-09-04
PhilipsFL1.20Noise on high volumePerform the following modifications on the SSP: Add on position 3618 4,7nF (4822 122 31784) Add on position 3619 jumper (4822 051 10008) Connected in series from 2604/4610 to earth. Change position 4610 into 1k ohm (4822 051 10102)14-09-04
PhilipsFL1.20Overview of SOPS repair kitsOverview of SOPS repair kits ---------------------------- FL1.0 AG00 upto AG03 4822 310 20492 FL1.0 AG04 and higher 4822 310 31921 FL1.1 25" and 28" 4822 310 31919 FL1.1 33" 4822 310 31932 FL1.2 4822 310 31932 FL1.6 14-09-04
PhilipsFL1.20Picture twists from topVoltage of pin 8-IC7450 (TDA3654Q) on the LSP has raised to ca. 20 V. Check diode 6451 (BZX79/C3V6; 5322 130 34834 or BZX79/C10; 4822 130 61219) 14-09-04
PhilipsFL1.20Set inoperative only red or green LED. Supply was 141V but no EHT.Line drive puls for T7506 (2SC4288A) too low. L5503 defective (Line drive coil; 4822 157 63252) 14-09-04
PhilipsFL1.20Sometimes vibration in vertical direction.Replace C2410 (150nF 5%; 4822 121 41854) on LSP. 14-09-04
PhilipsFL1.20Supply +5V too low, black horizontal bar in picture. Bad sync.Check/replace IC7551 (LM358N; 4822 209 70672) 14-09-04
PhilipsFL1.20Supply switch-off sometimesCheck the +5 stand-by. This voltage has to be 5.5V and may not vary. When the voltage drops below 5.2V the set switches-off. Cure: check D6266 for leackage (BZX79/F6V8; 4822 130 34278) or check T7268 for leackage (BD943F; 4822 130 62742). The 5.5V is meas14-09-04
PhilipsFL1.20Various faults can be observed.Check the earth connection from the SSP: connect earth tuner with earth line output transformer (LSP) to find-out whether the problem is solved. Check connectors L02 and S02 pins 1,2 (sometimes only 7 wires are used in the connector) 14-09-04