PhilipsFL2GBad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla14-09-04
PhilipsFL2GDark pix. No luminance (Y) signal.Cap 2327 (100nF) on SSP between pin 15 of IC 7324 (TDA4670) and ground leaky. No `Y' output from TDA4670. Replace 2327. 14-09-04

PhilipsFL2GHigh failure of PTCFor main input 100V: Change position 3020 and 3021 on the Large Signal Panel into 4822 116 40277 For main multi voltage: Change position 3020 and 3021 on the Large Signal Panel into 4822 116 40247 REMARKS : Introduced in production in week 955014-09-04
PhilipsFL2GNo picture or blue mute when other equipment is used in search modeDisable the blue mute by changing the option code. Decrease the original value with one.14-09-04
PhilipsFL2GPix folded at the bottomChange capacitor 2652 (1000 mF/50 volts). 2652 is filter cap for -14v supply. 14-09-04