Philips
FL2G
Bad focus or focus varies in a new set or after CRT replacement
Possible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla
14-09-04
Philips
FL2G
Dark pix. No luminance (Y) signal.
Cap 2327 (100nF) on SSP between pin 15 of IC 7324 (TDA4670) and ground leaky. No `Y' output from TDA4670. Replace 2327.
14-09-04
Philips
FL2G
High failure of PTC
For main input 100V: Change position 3020 and 3021 on the Large Signal Panel into 4822 116 40277 For main multi voltage: Change position 3020 and 3021 on the Large Signal Panel into 4822 116 40247 REMARKS : Introduced in production in week 9550
14-09-04
Philips
FL2G
No picture or blue mute when other equipment is used in search mode
Disable the blue mute by changing the option code. Decrease the original value with one.
14-09-04
Philips
FL2G
Pix folded at the bottom
Change capacitor 2652 (1000 mF/50 volts). 2652 is filter cap for -14v supply.