Make | Model | Problem | Solution | Date |
| | | |
Found: 6
|
Goodmans | W280NS Formenti F19 | Service mode access | Sw on TV holding in Vol+. Release vol button & press St/by on r/c within 3 secs. To save settings press yellow "mem" button else press TV/AV to exit without saving changes | 14-09-04 |
Proline | 1485R Daewoo Formenti | No line drive | I501 micro u/s Part no 1DW3813DE1 | 14-09-04 |
Proline | 1485R Daewoo Formenti | Reverts to st/by aft 65 secs | I501 micro u/s Part no 1DW3813DE1 | 14-09-04 |
Proline | 28N1 Formenti F19 | Dead - Chopper FET short. R8 O/C 390k | also replace TR1 P60NB80PF, | 14-09-04 |
Proline | 28N1 Formenti F19 | Vol cont bar will not move above 3 notches (not in hotel mode) | EEPROM corrupt - enter service mode by pressing "vol up" on TV whilst sw set on & within 3 sec's press "standby" on R/C (still holding "vol up"). Service mode options now on screen. Make a note of settings!! Scroll up to "INIT CTVFOR-P V1.3" press "vol up" (toggle) & wait 2 sec's to finish. | 14-09-04 |
Proline | F205T Formenti PC230 | Dead - mains i/p fuse blown | C415 1nf 1kv (blue pulse type) situated near the SMTX on the primary side. It was split | 14-09-04 |