Blaupunkt | FM120 | Long time to come on | C420 1µ 63v, C426/429 100µ 25v & TDA4600 | 14-09-04 |
Blaupunkt | FM120 | Tripping at sw on | LOPTx arcing | 14-09-04 |
Loewe | M124 | Bottom foldover | C581 47µ 25v | 14-09-04 |
Loewe | M124 | Int weak contrast | dry joints front controls & pcb | 14-09-04 |
Loewe | M124 | Lack of height | dry joints field o/p chip & height pot | 14-09-04 |
Loewe | M124 | No cold start | C624 100µ, C638 1µ | 14-09-04 |
Loewe | M124 | Small, flat pic with non-lin field | C652, 653 47µ 250v | 14-09-04 |
Lowe | M124 C8500 | Dead with 1.6A fuse blown | TDA4601 chopper chip s/c, small blue therm in start up cct, T539 BU508D LOPTr hi res | 14-09-04 |
Lowe | M124 C8500 | High HT (should be 142v) | C652 47µ 250v ; C653 47µ | 14-09-04 |
Lowe | M124 C8500 | Pic jitter & /or hum on pic with chan display flickering, sound goes low & controls not working int | Check for dry joints in psu, front pcb & IR receiver | 14-09-04 |
|
Panasonic | M12C | No go often int. | R513 680R DRY | 14-09-04 |
Sharp | 37AM12H | Poor pic/sound - noisy | Unable to get correct results in service mode - NVM pt no CH-IX1463CJHC | 14-09-04 |
Sharp | 37AM12S | Service Menu to acces service mode | Power off at switch
Hold -Volume & +Ch & turn set on switch (set should be service mode)
Press Ch+ until NVM (last service setting)
Now use volume control on remote change top (red) setting to "C5"
Now press "0" on the remote
Now put set into standby
Now turn set of at switch
The set should now be able to be tuned in | 14-09-04 |
Sharp | 51AM-12G | red raster with flyback lines then shuts off | Q875 on crt base - measured ok out of cct | 14-09-04 |