Make | Model | Problem | Solution | Date |
| | | |
Found: 28
|
ITT | PICO S3 | DEAD IF SCAN COILS DISCONNECTED TRIES TO RUN | WIDTH CCT ON SCAN COILS SC | 14-09-04 |
ITT | PICO S3 | STBY LED FLICKERS BUT DEAD . PIN 4 LOPTX REMOVED P | LOPTX US | 14-09-04 |
ITT | CP3106 Pico S | Frame - reduced. | If IC401 pin 9 down to 19v suspect LOPTX. | 14-09-04 |
ITT | CT3315 Pico S | Dark picture. | 270k resistor in 1st anode supply. | 14-09-04 |
ITT | CT3325 Pico S | No colour after few hours. | T1410 in tuner control unit ( IFB351 ) | 14-09-04 |
ITT | Pico | Dead - PSU not operating | ZPY120 120v over volts zener leaky | 14-09-04 |
ITT | Pico | Will not startup - LTB loaded. | Disconnect scan coils if sounds better then LOPTX. | 14-09-04 |
ITT | Pico 1 | Dark pic | TDA3561 u/s | 14-09-04 |
ITT | PICO 1 | PICTURE DARK ( NOT A1 SUPPLY ) | TDA3561 | 14-09-04 |
ITT | Pico 1A | Dead - with rapid ticking | No HT - D658 120v zener leaky | 14-09-04 |
|
ITT | Pico 1A | Tuning - will not tune in. | R1154 ( 2.2k ) o/c , D1151 ( reads ok ) | 14-09-04 |
ITT | Pico S | Bad hum bar & no sound | Replace 4 x 1N4007 mains rects | 14-09-04 |
ITT | Pico S | Blank raster with line tearing - sound int | C524 10µ | 14-09-04 |
ITT | Pico S | dead | 2A fuse on front panel o/c; degauss therm caused it | 14-09-04 |
ITT | Pico S | Dead. | Check small LT transformer for o/c. | 14-09-04 |
ITT | Pico S | Display shows "88" | SAA1292 chip faulty - caused by dry joints esp on C10 1000µ | 14-09-04 |
ITT | Pico S | Int dead when heated | 115v HT still present; dry joints LOP tr | 14-09-04 |
ITT | Pico S | Misty pic - poor col with red flaring | Earthing ring on crt base shorting to cathodes | 14-09-04 |
ITT | Pico S | No sound | R1075 3R3 safety res o/c; C229 220µ s/c | 14-09-04 |
ITT | Pico S | Pulling/bouncing/int loss of sound | C212 10µ 50v in CMR800 (top of can) | 14-09-04 |
ITT | Pico S | St/by only | relay clicks at sw on but no HT to LOP Tr; C701 10µ 350v faulty | 14-09-04 |
ITT | Pico S2 | Dead - no relay click at switch on. | Standby mains transformer primary winding o/c. | 14-09-04 |
ITT | Pico S2 | Dead - no relay click or display | Mains st/by tfmr o/c pri | 14-09-04 |
ITT | Pico S3 | Dead - life restored if scan coils dis'd | Width control coil on scan coils has shorted turns | 14-09-04 |
ITT | Pico S3 | Dead apart from brief led flicker at sw on | LOPTx | 14-09-04 |
Solavox | 16R19 NOKI PICO | BLANK PIC & LINE TEARING switch on off several tim | C524 10uF | 14-09-04 |
Solavox | 16R19 Pico S2 | Dead - no relay click at switch on. | Standby mains transformer primary winding o/c. | 14-09-04 |
Solavox | 20T19 Pico S | TEXT JUST A PATTERN | R21 O.C. - DATA SUPPLY TO | 14-09-04 |