Make | Model | Problem | Solution | Date |
| | | |
Found: 9
|
Bush | 28ZFK WST66 | Dead set. TP2 (FET) Blown and also diode in bridge rectifier cct. | Fit new FET(I fitted a BUZ91 type instead of a P4NA80FI) and IN4007 diode in bridge cct | 14-09-04 |
Bush | 28ZKFWST66 | Blank raster | Check TP6 BD441 5v reg, dry joints chopper trfmr | 14-09-04 |
Bush | WST66 | Dead - LOPTr S2000AF-1 s/c | When replaced, loud crack & went the same way as predecessor - LOPTx arcing thro pinhole | 14-09-04 |
Bush | WST66 28ZKF | Trips once then dead - LOPTr S2000AF1 s/c | LOPTx cause - FAT30564 ?19.38 SEME | 14-09-04 |
Bush | WST66 4400 | Dead - LEDs ok & EHT rustle | No 5v supply pin 39 & 44 of ICR1 & TP6 - BD441 faulty | 14-09-04 |
Bush | WST66W/S | Int start up; blank screen; no R/C operation | TP6 BD441 in st/by 5v supply - check heatsink clip secure | 14-09-04 |
Goodmans | GVT66W1 11AK19 | Lack of width & E/W faulty | R629 2R7 1/3w safety res o/c | 14-09-04 |
Goodmans | GVT66W1 11AK19 | To enter service mode | Call up install menu then pres 4, 7, 2 & 5 in order | 14-09-04 |
Hitachi | CPT6608 | Dead or Int dead | Check C524 C525 C527 C528 C531 C614 C617 for D/J also TR130 IC130 IC140 & around Combi TX | 14-09-04 |