MakeModelProblemSolutionDate
Found: 18
GoodmansW280NS Formenti F19Service mode accessSw on TV holding in Vol+. Release vol button & press St/by on r/c within 3 secs. To save settings press yellow "mem" button else press TV/AV to exit without saving changes14-09-04
NordemendePRESTIGE 72CAN'T TUNE COECTLY SET CAN'T SELECT UHFBACKUP BATTERY US14-09-04

NordMendePrestige 72Tuning difficulties - only goes up to Ch23Back up battery14-09-04
Proline1485R Daewoo FormentiNo line driveI501 micro u/s Part no 1DW3813DE114-09-04
Proline1485R Daewoo FormentiReverts to st/by aft 65 secsI501 micro u/s Part no 1DW3813DE114-09-04
Proline28N1 Formenti F19Dead - Chopper FET short. R8 O/C 390kalso replace TR1 P60NB80PF,14-09-04
Proline28N1 Formenti F19Vol cont bar will not move above 3 notches (not in hotel mode)EEPROM corrupt - enter service mode by pressing "vol up" on TV whilst sw set on & within 3 sec's press "standby" on R/C (still holding "vol up"). Service mode options now on screen. Make a note of settings!! Scroll up to "INIT CTVFOR-P V1.3" press "vol up" (toggle) & wait 2 sec's to finish.14-09-04
ProlineF205T Formenti PC230Dead - mains i/p fuse blownC415 1nf 1kv (blue pulse type) situated near the SMTX on the primary side. It was split14-09-04
SamsungTI 20C5DF2STries to start up with relay clicking then shuts down - vcr sect okTDA8356 field IC & R303 10R14-09-04
SamsungTI14C5DeadOpto coupler14-09-04
SamsungTI20C5DF2S/XEVDead except for cycling on/off of degaus relayC414 680pf 2kv burnt & leaky in lop stage14-09-04
SamsungTI20C5DF2S/XEVDead except for cycling on/off of degaus relayC414 680pf 2kv burnt & leaky in lop stage14-09-04
Schneider26" (It can also be found as Koerting model 26)Starts but it is not possible to change programs or to search for channels.Change Control chip SDA2030-A00214-09-04
Schneider26" (It can also be found as Koerting model 26)Won't start, PS protection active.Desolder Vertical IC, if it starts, change it.14-09-04
Siemens/BlaupunktChassis100/21 (Control section with hybrid Siemens Ics)Set can not be switched to Stby with the remote control. All other functions O.KSwitch the TV to Stby from the on/Stby switch on the front panel.Hold down the"ME" button and switch the TV on.Press CS. It should work normally now.14-09-04
Siemens/BlaupunktChassis100/21 (Control section with hybrid Siemens Ics)To set normal values for Bright/Contr/Col/VolumeSwitch set to Stby. Hold down "ME"button, until set switches on. Adjust bright,contr etc and press "ME" again to memorise.14-09-04
Siemens/BlupunktChassis100/21 (Control section with hybrid Siemens Ics)Set can not be switched to Stby with the remote control. All other functions O.KSwitch the TV to Stby from the on/Stby switch on the front panel.Hold down the"ME" button and switch the TV on.Press CS. It should work normally now.14-09-04
Siemens/BlupunktChassis100/21 (Control section with hybrid Siemens Ics)To set normal values for Bright/Contr/Col/VolumeSwitch set to Stby. Hold down "ME"button, until set switches on. Adjust bright,contr etc and press "ME" again to memorise.14-09-04