Goodmans | F19 W280NS | Dead | Volts on IC1 pulsing & no volts pin 1 - R7 10k hi res | 14-09-04 |
Goodmans | F19 W280NS | No sound | Put set in service mode & press vol up button | 14-09-04 |
Goodmans | F19 W280NS | No vol adj or sound menu | Dry joints Skt A13 on main pcb from NICAM panel | 14-09-04 |
Goodmans | W280NS | Dead - arcing LOPTx killed it | SEME type 1362.5001 code is LOPTX1324 ?27. The orig no. 1372.0066A | 14-09-04 |
Goodmans | W280NS | Dead - repeatedly blows LOPTr | LOP tuning cap 15nF dry jointed | 14-09-04 |
Goodmans | W280NS | Service mode entering | With TV off, press & hold middle button of 5 under flap. Press on off button whilst still holding button for
3 secs then press st/by on handset. Store with yellow button | 14-09-04 |
Goodmans | W280NS | Tripping | Dry joints C68 & C71 & LOPTr slightly leaky | 14-09-04 |
Goodmans | W280NS Formenti F19 | Service mode access | Sw on TV holding in Vol+. Release vol button & press St/by on r/c within 3 secs. To save settings press yellow "mem" button else press TV/AV to exit without saving changes | 14-09-04 |