Alba | VTV19 Combi | No pic - sound ok | C480 10µ near line dr tr | 14-09-04 |
Daewoo | Combi | Child lock removal | Press Bule-Yellow-Green-Red within 5-10 secs then press st/by twice | 14-09-04 |
|
Ferguson | C3615U Combi | Switches off aft 10 secs with tape jammed | RW002 1R 1w safety res on deck pcb - also check fuse link FW003 (behind on/off sw near white ribbon conn) | 14-09-04 |
Goldstar | KBV-9012E TV/VCR Combo | White raster with retrace lines, the set switches off after a while. L901 (in series with +180V supply to RGB trs) oc, the +180V winding of Loptx delivers 300V!! (Di&smooth.Cap OK) | Replace C820 10uF/160V cap. Note that +180V supply delivers 300V, while +B and all other voltages are normal. Seems to be a weird LOPTx fault, but it was C820 instead. | 14-09-04 |
Goldstar | KBV-9012E TV/VCR Combo | White raster with retrace lines, the set switches off after a while. L901 (in series with +180V supply to RGB trs) oc, the +180V winding of Loptx delivers 300V!! (Di&smooth.Cap OK) | Replace C820 10uF/160V cap. Note that +180V supply delivers 300V, while +B and all other voltages are normal. Seems to be a weird LOPTx fault, but it was C820 instead. C820 IS NOT the smoothing cap for +180V. | 14-09-04 |
Hinari | VTV100 Combi | Raster - high raster. | Q301 ( 2SA1015 or BC307 ) s/c. | 14-09-04 |
JMB | JMB66W 11AK19Pro | Dead - LED lit green but no line drive | pin 40 TDA8844 s/c. There is an internal diode between pin 40 & ground that goes leaky, replace the IC or burn diode o/c by applying 5V between pin 40 & ground from ext psu | 14-09-04 |
JMB | JMBM020FTS PT92-90deg | No col, ragged verts & causing interference on hearby tvs | LOPTx - (pt-10677080) (FBT40784) from Wiltsgrove @ 14.75UKP's.arcing at bottom where EHT lead is pushed in | 14-09-04 |
JMB | JMBN028WSS | E/W dist with burning smell | RV38 8R2 in LOP o/c, CD21 680nF 250v o/c | 14-09-04 |
LG | KE14U73 Combi | Swirling lines & static pops on pic | poor earthing of the deck to the screen large VCR screening can | 14-09-04 |
Matsui | MB10 | Dead on mains - ok on 12v | 4700pf 2kv cap on print side of board not shown in cct diag was s/c | 14-09-04 |
Matsui | MB10 | No psu start up | Q805 2SC2120Y leaky - BC639 used in lieu | 14-09-04 |
Philips | 14PV182 combi | Dead with tape stuck in machine | LOPTx | 14-09-04 |
Philips | 14PV284 Combi | Some buttons on handset not working | It should be noted that the VCR buttons on the remote can be set to VCR 2 coding although this is not a documented feature. This will result in the VCR part of the Combi not working via remote. Pressing 'STOP' and '2' together on the remote changes the code to VCR 2. Pressing 'STOP' and '1' together on the remote will change the code back to VCR 1. The TV controls are unaffected.Removing the batteries and pressing any button then refitting the batteries will also set the code back to VCR 1.
Note that the remote should be set to VCR1 for the VCR buttons to work the Combi. | 14-09-04 |
Philips | Combi | Remote control not responding | Check not set to VCR2 - press Stop & 1 together or removing batts will restore VCR1 setting | 14-09-04 |