Make | Model | Problem | Solution | Date |
| | | |
Found: 5
|
Finlux | 1000 (early) | Int col with TDA3652A chip | ref osc trimmer Ct12 6-30pf noisy. To set up link pins 24/25 & 1/5 of ic & adj Ct12 for stationary col | 14-09-04 |
Finlux | 1000 early | No pic - crt htrs alight | Cb 2µ2 35v o/c (near col dec chip) | 14-09-04 |
Finlux | 1000 srs EARLY | INT COLOUR , SEEMS LIKE DRY JOINTS | Ct12 REF OSC TRIMMER NOISY . LINK PINS 25 , 26 AND 1 , 5 TO SETUP | 14-09-04 |
Goodmans | 1432 early | Poor interlace effect when VCR played | C117 2µ2 50v in IF can | 14-09-04 |
Philips | GRl-AX | Intermittently dead | The cause of this nasty fault turned out to be a small coil , L5524 , which filters the supply to the line driver stage. It was | 14-09-04 |