MakeModelProblemSolutionDate
Found: 4551
PhilipsG90AESET DEAD WORKS IF SUPPLY REDUCED TO 90vD665314-09-04
PhilipsG90AESet intermittently tripping.Suspect fault around trip circuit comprising T7655/7656. Replace zener diodes 6657, 6658, 6659 and especially 6655 - 15 volt zener.14-09-04

PhilipsG90AEShut down aft 10 mins with HT low at 30vTr7652 BC557C - check it with freezer14-09-04
PhilipsG90AESHUTS DOWN , TICKING NOISE FROM PSUPT7652 ( BC557C ) LEAKY , THEN RAGGED R3668 ( 150R ) AND FIT NEW HT RESERVIOR CAP 47mfd C263014-09-04
PhilipsG90AEShuts down on full mains - ok on 90v acNot a prot fault - D6653 leaky (supplies opto coupler)14-09-04
PhilipsG90AEShutting down with a ticking PSU.Tr7652 ( BC557C ) leaky , R3668 ( 150ohm ) scorched , Check C2630 HT res14-09-04
PhilipsG90AESound intD6272/6278 BAS32 sm in series with 20v supply to sound chip IC7220 TDA819114-09-04
PhilipsG90AESpare part informationSpare part information Codenumber channel selector UV615 including hyperband is 4822 210 10374.14-09-04
PhilipsG90AESqueal from psu - sound & pic okR3614 360k; R3618,R3620 180k; C2630 47µ (HT res cap)14-09-04
PhilipsG90AESqueal from psu (sound & pic ok)Renew the three bridge sm resistors 3620 (180K), 3618 (180K) and 3614 (360K) and the Ht decoupler C2630 (47mfd / 160v)14-09-04
PhilipsG90AEStriationsA production change has been introduced adding the following components in the +95 volt feed to the line output stage: Description: Position no. 5558 Code no. 4822 158 10563 Choke 82uH Capacitor 10n 100V Position14-09-04
PhilipsG90AEStuck on chan 8, front controls & R/C inop - st/by led flashingReplace C2843 [220uf] in 5 volt regulator14-09-04
PhilipsG90AESwitches off and on shortlySelects always program 1 and adjusts PP-value.Check C2397 (33nF; 5322 121 41763) on the CRT panel for leakage. Bend C2397 on picture-tube PCB from picture-tube socket.14-09-04
PhilipsG90AEThe upper part of picture consists of few linesCheck C2475 (33nF/63V; 5322 122 31848). 14-09-04
PhilipsG90AEThe voltage of +95V line altersCheck transistor 7653 (BC858A; 5322 130 42012). 14-09-04
PhilipsG90AETrippingIf HT set at 95v tripping stops but blank raster. Xtal filter 1030 s/c with solder14-09-04
PhilipsG90AETripping aft 10 mins operationCan be instigated by heating/cooling around psu - replaced 150R sm (R3668?)14-09-04
PhilipsG90AETripping with clcking thro spkrSame on dummy load - Replace C2630/1 47µ 160v. R3668 sm 150R had dropped off. Replaced also 7652 BC557C & opto coupler as precaution14-09-04
PhilipsG90AETrips on & off violently aft several minsOzone smell - focus pin arcing - replace crt base14-09-04
PhilipsG90AETrips rapidlyTr7652 BC557C in pulse width mod in psu14-09-04
PhilipsG90AETuning unstableVoltage on diode D 6770 not stable Replace D 6770 (ZTK 33B; 4822 130 30959)14-09-04
PhilipsG90AETuning, display and remote control not functioningVoltage of pin 42-IC7720 low, TR7661 defective (BD135; 4822 130 40823).14-09-04

PhilipsG90AETXT horizontal synchronization missingCheck horizontal phase discriminator detection filter capacitor C2827 (47nF; 4822 122 32542).14-09-04
PhilipsG90AETxt poor - looks like purity errorsDry joints wire links on main pcb near Txt panel14-09-04
PhilipsG90AEWeak video & no syncTDA585014-09-04
PhilipsG90AEWhen fitting psu mod kitDiodes 6608 & 6609 should be wired in series and then connected between base/emitter of 7625 (BUT11AF) with the anode end of the pair to base. (if not already fitted)14-09-04
PhilipsG90AEWhen the set is switched on, the SOPS starts tripping.If the mains voltage is turned up using a variac, the +95 line supply gets to 80 volts then starts pulsing. Check/replace R3668 - 150 Ohms SMD (5322 111 90098)14-09-04
PhilipsG90AEWhite screen, not adjustableCheck POR-transistor 7663 (BC858; 5322 130 42012). 14-09-04
PhilipsG90AEWill not stay in Standby modeThe reason of this fault is R3669 220 Ohm in the Power supply. Service code 4822 051 10221.14-09-04
PhilipsG90AEWont go into st/by - LED goes orange not redD6669 BAS32 s/c14-09-04