datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Solaflow Seminar II

Solaflow Seminar II free download

Various electronics service manuals

File information:
File name:SeminarII_UserManual.part2.rar
Size:1939 kB
Extension:rar
Mfg:Solaflow
Model:Seminar II 🔎
Original:Windpower Australia 🔎
Descr:Seminar II solar controller
Group:Electronics > Other
Uploaded:17-05-2011
User:personlogin
Multipart: 0  1

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name SeminarII_UserManual.pdf

WINOPOWER AUSTRALIA SEMINAR II USER MANUAL ADDENDUM The following sections have been changed in the User manual and should now read as follows: General Note: The real time clock only operates in the 24 hour mode (2 pm = 14.00 Hours). Please ensure when programming the Seminar II Time Of Day that you bear this in mind. 5.0 MEASUREMENT CHARACTERISTICS Table Two below shows the values measured by the Seminar II , the accuracy of the measurement and the number of digits displayed. Measured Value Battery Voltage Battery Current Solar Voltage Solar Current Battery temperature Full Scale Reading 199.9 '! 750A 199.9 Digits Displayed 3 1;2 3 31;2 3 3 Accuracy ± 0.1 v v 75 0 A 37.0 oc 1% ± 1 digit ±0.1 v ±0.1 A ± 0.5 oc Table Two: Measurement Characteristics 7.5 Battery Current The Battery Shunt termination's are provided on the right hand end of the SEMINAR II. They are colour coded, RED for the load side, BLACK for the battery negative side, see Figure 5 below. THE MEASURING SHUNT MUST BE CONNECTED IN THE NEGATIVE LEAD GOING TO THE LOAD. Note: The Battery Negative of the Seminar II should be connected to the Shunt side of the fuse. Seminar// Version 1 Addendum Page: 1 W INDPOWER AUSTRALIA SEMINAR II LOW BATTERY OUTPUT WILL SWITCH UP TO 250 MA LOAD EITHER relay AUXILLARY BATTERY ~ + OR diode Figure Five : Seminar II Connection diagram The foUowing section has been added: 8.0 Alarm Conditions The Seminar II has been programmed to warn of four alarm conditions. These are shown in Table Four below. or. ·, ,.~/~J..g, ~..L w;ll ~ (;J. ~ _n,.,J.. I FAULT I On initialisation { Battery Volts LED flashing Piezo Buzzer sounding PROBLEM Battery voltage outside Battery 0% - 100 % ran~e - c.c.,._ ~ ck,k..-1 $~1" w ~ ~' ·"' )k.l/t;J.u~ Solar Volts and Amps LED's Solar Panel disconnected or flashing faulty Piezo buzzer sounding ACfiON Connect load across battery to reduce voltage or charge battery to increaS<;? the voltage. ~~... ~.(.. )UI't- ~ys cri'W Press SCROLL button to cancel buzzer. Check Solar panel and connections. Low Battery LED and LCD Battery voltage has gone Press SCROLL button to cancel buzzer. display showing below Low Battery on value. Piezo buzzer sounding Reduce load and/or charge Battery. Battery Volts LED flashing. Temperature probe faulty or Press SCROLL button to cancel buzzer. Piezo buzzer sounding disconnected. Reconnect temperature probe or remove and return for repair. dL Table Four : Fault, Problem and Action summary. Semlnarfl Version 1 Acldeodum Page: 2 WINDPOWER AUSTRALIA 8.1 System Volts On initialisation, if the battery voltage is not within one of the ranges for the systems as shown in Table I, the Battery Volts LED will flash and the piezo buzzer will sound. The display will show the actual voltage measured. The program will continue to measure the battery voltage and test to see if it is within range. [fit detects the voltage within range it will display the system voltage selected and remove t



>> Download document << eServiceInfo Context Help
Attention! This manual is multipart. Download all, before decompressing



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Solaflow Seminar II -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Panasonic sa ak600

script execution: 0.02 s