datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent HP 11683A H01 ops service

Agilent HP 11683A H01 ops service free download

Various electronics service manuals

File information:
File name:HP 11683A H01 ops_service.pdf
[preview HP 11683A H01 ops service]
Size:956 kB
Extension:pdf
Mfg:Agilent
Model:HP 11683A H01 ops service 🔎
Original:HP 11683A H01 ops service 🔎
Descr: Agilent HP 11683A H01 ops_service.pdf
Group:Electronics > Other
Uploaded:25-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name HP 11683A H01 ops_service.pdf

OPERATING AND SERVICE MANUAL SPECIAL SUPPLEMENT 11683A OPTION H01 POWER METER RANGE CALIBRATOR 11683-90010 Model Number: 11683A Option H01 Part Number: 11683-90010 Date Printed: March 2007 2 Description ... 4 Specifications... 4 Operation ... 4 Performance Test ... 5 Caution... 5 DVM Reading (OHM)... 6 Replacement Parts ... 6 3 Description The 11683A Option H01 is a standard 11683A range calibrator that has been modified so that it will operate with either the Internal DC-Reference source, or an external programmable DC-Reference source. Specifications External DC Reference is the same as the Internal Reference. Operation The 11683A Option H01 Range Calibrator allows a user to select either an internal or an external DC-Reference source. With the REF SELECT switch in the INT position, the range calibrator is operating manually with the Internal DC-Reference source. With the REF SELECT switch in the EXT position, the range calibrator can be programmed remotely with a programmable DC source. In this mode of operation, the REF SELECT switch disconnects the internal DC source, and connects the external DC source to the sampling gate assembly (A3). In all other respects, the 11683A Option H01 operates the same as the standard 11683A. The typical input voltages corresponding to the different range settings are: Range Volts 100 mW 15.800V 30 mW 4.7121V 10 mW 1.4641V 1 mW 145.00 mV 300 uW 45.837 mV 100 uW 14.494 mV 30 uW 4.5832 mV 10 uW 1.4501 mV 3 uW 458.69 uV The above calculated voltages for range 100 mW to 300 uW ar

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : LG LG HT306PD AFN75354522

script execution: 0.09 s