datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent HP 5517C CHAPTER 5 USER

Agilent HP 5517C CHAPTER 5 USER free download

Various electronics service manuals

File information:
File name:HP 5517C CHAPTER 5 USER.pdf
[preview HP 5517C CHAPTER 5 USER]
Size:763 kB
Extension:pdf
Mfg:Agilent
Model:HP 5517C CHAPTER 5 USER 🔎
Original:HP 5517C CHAPTER 5 USER 🔎
Descr: Agilent HP 5517C User HP 5517C CHAPTER 5 USER.pdf
Group:Electronics > Other
Uploaded:26-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name HP 5517C CHAPTER 5 USER.pdf

5 Laser Heads Chapter 5 Laser Heads General General One laser head is required in most measurement systems, regardless of the number of measurement axes in the system. The wavelength of light from the laser head is used as the length standard for Agilent laser measurement systems. The laser head generates a coherent (all light waves in phase), collimated (all waves traveling parallel to one another), light beam consisting of two orthogonally polarized frequency components. To differentiate between the frequencies, the lower frequency is identified as f1 and the higher as f2. The difference between these two frequencies is the "Reference Frequency", listed in Table 5-1. Agilent offers several laser head models to fill a variety of requirements. A summary listing of Agilent laser heads is provided in Table 5-1. In addition to system information for the laser heads, complete descriptions, equipment supplied information, and specifications for each laser heads are given in this chapter. Each of these laser heads requires a cable to connect it to the measurement system electronics. Cables are listed in Chapter 9, "Accessories," of this manual. Table 5-1. Laser Heads Summary Agilent Reference Beam Model Requency Diameter Polarization Indicators Shutter 5517A 1.5 MHz to 6 mm f1 Horiz LASER ON Open, reduced, 2.0 MHz f2 Vert READY closed 5517B 1.9 MHz to 6mm f1 Horiz +15V POWER ON Open, reduced 2.4 MHz f2 Vert -15V POWER ON closed LASER ON READY 5517C 2.4 MHz to 6 mm (std) f1 Horiz +15V POWER ON Open, reduced 3.0 MHz 3 mm (5517C-003) f2 Vert -15V POWER ON closed 9 mm (5517C-009) LASER ON READY 5-2 User's Manual Chapter 5 Laser Heads Frequencies and Polarizations Table 5-1. Laser Heads Summary (Continued) Agilent Reference Beam Model Requency Diameter Polarization Indicators Shut

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Technics A700

script execution: 0.07 s