datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent 1952-05

Agilent 1952-05 free download

Various electronics service manuals

File information:
File name:1952-05.pdf
[preview 1952-05]
Size:982 kB
Extension:pdf
Mfg:Agilent
Model:1952-05 🔎 195205
Original:1952-05 🔎
Descr: Agilent journals 1952-05.pdf
Group:Electronics > Other
Uploaded:26-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 1952-05.pdf

HEWLETT-PACKARD JOURNAL T E C H N I C A L I N F O R M A T I O N F R O M T H E - h p - L A B O R A T O R I E S Vol. 3 No. 9-10 PUBLISHED BY THE HEWLETT-PACKARD COMPANY, 395 PAGE MILL ROAD, PALO ALTO, CALIFORNIA MAY-JUNE, 1952 The -hp- Direct -Reading UHF Signal Generators THE -hp- Model 616A UHF Signal Gen Both generators provide c-w, pulse, and erator was designed as the first commer f-m type outputs. A versatile internal pulser cially-available direct-reading signal gener permits the pulse modulation to meet a va ator for the upper UHF region. It operates riety of requirements as to pulse rate, pulse over the range from 1800 to 4000 megacy length, and synchronization. The character cles. A second generator, the -hp- Model of typical output pulses is illustrated in Fig. 2. 614A, was subsequently developed for use Probably the most common use for signal over the 800 to 2100 megacycle range as a generators is in testing receivers. For re companion instrument for the 61 6 A. The ceiver testing, it is desirable that the output 6l4A and 6l6A are similar in all character power from the generator be adjustable istics except frequency range. down to very low levels. Thus, the 61 4 A and Both generators have three outstanding 61 6 A have been designed to provide outputs characteristics that give them a high degree as low as 0.1 microvolt. This low level is of usability: they are direct-reading in fre more than sufficient to test present receivers. quency, direct-reading in output power, and The matter of high output from the gener cover a wide frequency range. The very real ator is of secondary importance in receiver value of these characteristics will be recog testing. A maximum generator output in the nized at once by those who have worked order of a hundred microwatts is usually with frequency charts and power

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : LG D-27

script execution: 0.07 s