datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12]

Agilent 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12] free download

Various electronics service manuals

File information:
File name:5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12].pdf
[preview 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12]]
Size:1452 kB
Extension:pdf
Mfg:Agilent
Model:5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12] 🔎
Original:5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12] 🔎
Descr: Agilent 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12].pdf
Group:Electronics > Other
Uploaded:31-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12].pdf

Keysight Technologies CXA X-Series Signal Analyzer N9000A Configuration Guide Configure Your Keysight CXA Signal Analyzer This CXA configuration guide will help you determine which performance options, measurement applications, accessories, and services to include with your new CXA or to add as upgrades to an existing CXA. This step-by-step process will help you custom-configure your CXA signal analyzer. Capabilities that are listed as standard come with the instrument at no additional charge. Tailor the performance, exterior, and service packages to meet your requirements. Ordering optional capabilities at time of purchase provides the lowest overall cost. For detailed specifications, refer to the CXA Signal Analyzer Specification Guide (N9000-90016). For a summary of specifications, refer to the CXA Signal Analyzer Data Sheet (5990-4327EN). Step 1. Select maximum frequency range (required option; frequency range not upgradeable) Description Option number Additional information Frequency range, 9 kHz to 3.0 GHz N9000A-503 Frequency range, 9 kHz to 7.5 GHz N9000A-507 Frequency range, 9 kHz to 13.6 GHz N9000A-513 Frequency range, 9 kHz to 26.5 GHz N9000A-526 Step 2. Add a preamplifier Description Option number Additional information: Preamplifiers improve the noise floor for low-level signal detection; +20 dB: 100 kHz to 26.5 GHz Preamplifier, 100 kHz to 3.0 GHz N9000A-P03 Compatible with N9000A-503, N9000A-507, N9000A-513, and N9000A-526 Preamplifier, 100 kHz to 7.5 GHz N9000A-P07 Compatible with N9000A-507, N9000A-513, and N9000A-526 Preamplifier, 100 kHz to 13.6 GHz N9000A-P13 Compatible with N9000A-513 and N9000A-526 Preamplifier, 100 kHz to 26.5 GHz N9000A-P26 Compatible with N9000A-526 Step 3. Choose frequency reference Description Option number Additional information Frequency reference Standard Aging rate:

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : IZUMI KD-035

script execution: 0.07 s